Command Reference
R&S
®
ZNC
390
User Manual 1173.9557.02 ─ 13
Parameters:
<Boolean>
ON | OFF - Fail beep on or off.
*RST:
OFF
Example:
CALCulate:LIMit:CIRCle:STATe ON; SOUNd ON
Switch the limit check on and activate the fail beep.
Manual operation:
See
CALCulate<Chn>:LIMit:CIRCle[:STATe]
<Boolean>
Switches the circle limit check on or off.
Suffix:
<Chn>
.
Channel number used to identify the active trace.
Parameters:
<Boolean>
Example:
*RST; CALCulate:LIMit:CIRCle:DATA 0, 0, 0.5
Define a circle limit line centered around the origin of the polar
diagram, assigning a radius of 0.5 U.
CALCulate:LIMit:CIRCle:STATe ON; FAIL?
Switch the limit check on and query the result.
Manual operation:
See
CALCulate<Chn>:LIMit:CIRCle:CLEar
Resets the limit check results for the circle test.
Suffix:
<Chn>
.
Channel number
Usage:
Event
Manual operation:
See
CALCulate<Chn>:LIMit:CONTrol[:DATA]
<FreqPowTime>, <FreqPowTime>...
Defines the stimulus values of the limit line and/or creates new limit line segments. See
also
chapter 3.4.1.1, "Rules for Limit Line Definition"
Rules for creating segments
The following rules apply to an active trace with n existing limit line segments:
●
An odd number of values is rejected; an error message -109,"Missing parameter..."
is generated.
●
An even number of 2*k values updates or generates k limit line segments.
●
For n > k the stimulus values of all existing limit line segments no. 1 to k are updated,
the existing limit line segments no. k+1, ..., n are deleted.
●
For n < k the stimulus values of the limit line segments no. 1 to n are updated, the
limit line segments n+1, ,..., k are generated with default response values (see
SCPI Command Reference