background image

Preface

R&S

®

SMW-K550

6

User Manual 1178.3263.02 ─ 01

General safety instructions, printed brochure

Release notes, see the product page (download > firmware)

Data sheet and brochures, see the product page (download > brochures and data
sheets)

Application notes, provided on the internet

You find the user documentation on the R&S

 

SMW product page mainly at:

www.rohde-schwarz.com/product/SMW200A

 

>

 

"Downloads" > "Manuals"

Additional download paths are stated directly in the following abstracts of the docu-
mentation types.

Getting Started

Introduces the R&S

 

SMW and describes how to set up and start working with the prod-

uct. Includes basic operations, typical measurement examples, and general informa-
tion, e.g. safety instructions, etc.

Online Help and Tutorials

The 

online help

 offers quick, context-sensitive access to the information needed for

operation and programming. It contains the description for the base unit and the soft-
ware options.

The 

tutorials

 offer guided examples and demonstrations on operating the R&S

 

SMW.

User Manual and Online Manual

Separate manuals are provided for the base unit and the software options:

Base unit

 manual

Contains the description of the graphical user interface, an introduction to remote
control, the description of all SCPI remote control commands, programming exam-
ples, and information on maintenance, instrument interfaces and error messages.
Includes the contents of the getting started manual.

Software option

 manuals

Describe the specific functions of an option. Basic information on operating the
R&S

 

SMW is not included.

The 

online manual

 provides the contents of the user manual for immediate display on

the internet.

Service Manual

Describes the performance test for checking the rated specifications, module replace-
ment and repair, firmware update, troubleshooting and fault elimination, and contains
mechanical drawings and spare part lists.

The service manual is available for registered users on the global Rohde

 

&

 

Schwarz

information system (GLORIS, 

https://gloris.rohde-schwarz.com

).

Documentation Overview

Содержание SMW-K550

Страница 1: ...R S SMW K550 Stream Extender User Manual User Manual 1178 3263 02 01 P 2 Test Measurement...

Страница 2: ...any Phone 49 89 41 29 0 Fax 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark...

Страница 3: ...3 Notes on Screenshots 8 2 Welcome to the R S SMW K550 Option 9 2 1 Accessing the Settings 9 2 2 Scope 10 3 Stream Extender Related Settings 11 4 Application Example GSM AM Suppression Test 13 4 1 Re...

Страница 4: ...Contents R S SMW K550 4 User Manual 1178 3263 02 01...

Страница 5: ...c procedure to perform signal generation tasks and step by step instruc tions for more complex tasks or alternative methods As well as detailed examples to guide you through typical signal generation...

Страница 6: ...re options The tutorials offer guided examples and demonstrations on operating the R S SMW User Manual and Online Manual Separate manuals are provided for the base unit and the software options Base u...

Страница 7: ...pplication Notes Application Cards White Papers etc These documents deal with special applications or background information on particu lar topics see www rohde schwarz com appnotes 1 3 Conventions Us...

Страница 8: ...ting procedures The term select may refer to any of the described methods i e using a finger on the touchscreen a mouse pointer in the display or a key on the instrument or on a key board 1 3 3 Notes...

Страница 9: ...8 streams out of 4 baseband signals Generation of 4 signals with real time data source for example to ensure non trun cated PN sequences Generation of wanted and interfering signals as required for th...

Страница 10: ...ttings and data lists like storing and loading settings creating and accessing data lists or accessing files in a particular directory Information on regular trigger marker and clock signals and filte...

Страница 11: ...ion System Configura tion 2 In the Fading Baseband Configuration dialog select Mode Advanced 3 Enable a 3x1x1 or a 4x1x1 configuration 4 Select Duplicate Streams On Confirm with Apply With the selecte...

Страница 12: ...per default 3 basebands and 3 streams The first two basebands can generate signals with real time data sources If Duplicate Streams On created is a copy of each stream after baseband fading block Gene...

Страница 13: ...ed signals The following example shows the configuration principle in general Not all required settings are shown The used settings do not comply with the specifi cation 4 1 Required Options The equip...

Страница 14: ...terfering signal and the wanted signals are routed to two separate RF outputs because of the difference in their power levels Both RF signals are connected to a combiner The sum signal is fed to the R...

Страница 15: ...ands the downlink frequencies are higher than the corresponding uplink frequencies The difference between downlink and uplink frequencies is termed the duplex spacing it is also band specific For an o...

Страница 16: ...MHz offset and the outer two at 12 MHz GSM transmission in timeslot 1 for both the 4 wanted and the interfering signals The interfering signal is a GSMK modulated PN9 sequence of 511 bits length The...

Страница 17: ...f the interfering signal as listed in TS 51 021 table 7 8 2 In this example the power levels of the wanted signals are 94 dBm and 98 dBm The interfering signal level is 31 dBm 5 In the baseband domain...

Страница 18: ...s are transmitted in timeslot 1 1 Select Baseband C GSM 2 Select Framed Single Configuration Per default the first timeslot 0 is active 3 To disable timeslot 0 and activate timeslot 1 In the frame gra...

Страница 19: ...for example Trigger Delay 70 Symbols 6 Configure the wanted signals in baseband A and B Load you own data lists as data source Configure the GSM bursts and frames according to the specification TS 51...

Страница 20: ...ion of the wanted and the interfering signals Note that the streams generated form the same baseband are not transmitted on nearby carriers Figure 4 3 Block diagram understanding the displayed informa...

Страница 21: ...m2 STATe 0 SCONfiguration OUTPut MAPPing IQOutput1 STReam3 STATe 0 SCONfiguration OUTPut MAPPing IQOutput2 STReam4 STATe 0 SCONfiguration OUTPut MAPPing BBMM1 STReam3 STATe 0 SCONfiguration OUTPut MAP...

Страница 22: ...3 SOURce1 BB GSM TRIGger EXTernal1 DELay 70 SOURce1 FREQuency CW 947200000 SOURce2 FREQuency CW 947200000 SOURce2 POWer POWer 31 SOURce1 POWer POWer 89 53 ENTity2 SOURce1 BB PGAin 4 SOURce1 ROSCillato...

Страница 23: ...nforma tion R S SMW K550 23 User Manual 1178 3263 02 01 Glossary 3GPP Specifications References Documents with Further Information T TS 51 021 Technical Specification Group GSM EDGE Radio Access Netwo...

Страница 24: ...List of Commands R S SMW K550 24 User Manual 1178 3263 02 01 List of Commands SCONfiguration DUPLicate STReam 22...

Страница 25: ...s 7 Application notes 7 B Brochures 7 BS receiver testing Introduction 13 D Data sheets 7 Documentation overview 5 Duplicate streams Access settings 11 Application example 13 Fading and baseband confi...

Отзывы: