Remote Control Commands
R&S
®
SMJ100A
601
Operating Manual 1403.7458.32 ─ 14
Parameters:
<Power>
float
Range:
-80 to 0
Increment: 0.01
*RST:
0
Default unit: dB
Example:
BB:ARB:MCAR:CARR15:POW -50 dB
sets the power of carrier 15 to -50 dB.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:POWer:REFerence
<Reference>
Defines the way the individual carriers in a composed multi carrier signal are leveled.
Parameters:
<Reference>
RMS | PEAK
*RST:
RMS
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:STATe
<State>
Enables/disables the selected carrier.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
SOURce1:BB:ARBitrary:MCARrier:CARRier15:STATe
ON
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CFACtor:MODE
<Mode>
The command sets the mode for optimizing the crest factor by calculating the carrier
phases.
SOURce Subsystem
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...