[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PULSe:FREQuency?
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PATTern
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:OFFTime
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:ONTime
Marker Delay
The delay of the signals on the MARKER outputs is set in the"Marker Delay" section.
Marker x Delay
Enters the delay between the marker signal at the marker outputs and the start of the
frame or slot.
The input is expressed as a number of symbols. If the setting "Fix marker delay to
dynamic range" is enabled, the setting range is restricted to the dynamic range. In this
range the delay of the marker signals can be set without restarting the marker and sig-
nal.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay
Current Range without Recalculation
Displays the dynamic range within which the delay of the marker signals can be set
without restarting the marker and signal.
The delay can be defined by moving the setting mark.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay:MINimum?
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay:MAXimum?
Fix marker delay to current range
Restricts the marker delay setting range to the dynamic range. In this range the delay
can be set without restarting the marker and signal.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut:DELay:FIXed
Clock Settings
The "Clock Settings" is used to set the clock source and a delay if required.
Clock Source
Selects the clock source.
"Internal"
The internal clock reference is used to generate the symbol clock.
Baseband Signal - Baseband Block
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...