Instrument Function
R&S
®
SMJ100A
309
Operating Manual 1403.7458.32 ─ 14
Remote command:
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:STEP[:INCRement]
Signal Monitoring
The section "Signal Monitoring" indicates digital signal clipping.
Overflow - Digital I/Q Out
Indicates that the I/Q output signal is currently clipped. This indication also appears in
the block diagram close to the digital I/Q Out connector.
Overload may occur, e.g. if the level of the output signal, or the noise level (AWGN)
are too high.
Remote command:
[:SOURce]:IQ:OUTPut:DIGital:OFLow:STATe?
Overflow Hold - Digital I/Q Out
Indicates an overflow since last reset.
The overflow hold state can be reset via the "Reset" button next to the LED, or is reset
automatically by starting a new signal generation or by setting new values to the output
level.
Remote command:
[:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:STATe?
Reset - Digital I/Q Out
Executes a reset of the overflow hold state and LED.
Remote command:
[:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:RESet
Power On Settings
The power on behaviour of the R&S
SMJ is set in the "Power On Settings" section.
Power-On State - Digital I/Q Out
Selects the state which the digital I/Q Output is to resume after the instrument is
switched on.
"I/Q Out Off"
The output is deactivated when the instrument is switched on.
"Previous Set-
ting"
When the instrument is switched on the digital I/Q output resumes to
the status that was active before the last switch off.
Remote command:
[:SOURce<hw>]:IQ:OUTPut:DIGital:PON
Connected Device - Digital I/Q Out
if the connection is properly established and signal transmission is active, this parame-
ter indicates the ID of an externally connected Rohde&Schwarz instrument.
Remote command:
[:SOURce<hw>]:IQ:OUTPut:DIGital:CDEVice?
Impairment of Digital I/Q Signal and Noise Generator - AWGN/IMP Block
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...