Remote Control Commands
R&S
®
SMB100A
463
Operating Manual 1407.0806.32 ─ 21
Example:
STEReo:DIRect "EON-AFB=1000,N,97.4,98.3"
Creates a new type B alternative frequency list for the EON with
PI=1000.
The list contains the alternative frequencies 97.4 MHz and 98.3
MHz.
Example:
STEReo:DIRect? "EON-AFB,1000,1"
Reads the first type B alternative frequency list of the EON with
PI=1000.
Response:
"97.4,98.3"
STEReo:DIRect
"EON-DEL=<PI>"
Enhanced Other Networks: deletes the complete EON with selected <PI>.
Parameters:
<PI>
Range:
0000 to FFFF (ASCII coded hexadecimal num-
bers)
Example:
STEReo:DIRect "EON-DEL=1000"
Deletes the EON with PI=1000.
Usage:
Setting only
STEReo:DIRect
"EON-PI=<PI>"
STEReo:DIRect?
"EON-PI"
Enhanced Other Networks: creates a new EON or reads the list of the program identifi-
cation (PI) codes of all EONs created so far.
Note:
A maximum of eight EONs can be created.
Parameters:
<PI>
Note:
A four-digit value must always be set. Leading zeros, if
any, must also be specified.
Range:
0000 to FFFF (ASCII coded hexadecimal num-
bers)
Example:
STEReo:DIRect "EON-PI=1000"
Creates a new EON with PI=1000.
Example:
STEReo:DIRect? "EON-PI"
Response:
"1000"
STEReo:DIRect
"EON-PS=<PI>,<PS>"
STEReo:DIRect?
"EON-PS,<PI>"
Enhanced Other Networks: sets the program service (PS) name for the EON with the
selected <PI>.
Parameters:
<PI>
Range:
0000 to FFFF (ASCII coded hexadecimal num-
bers)
Direct Commands for the Stereo/RDS Coder Option R&S SMB-B5