Remote Control Commands
R&S
®
SGT100A
437
User Manual 1176.8674.02 ─ 07
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:VOUT:MIN
<VoutMin>
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:VOUT:MAX
<VoutMax>
Queries the minimum and maximum values of the estimated envelope output voltage
V
out
.
Parameters:
<VoutMax>
float
Range:
0.04 to 8
Increment: 1E-3
*RST:
1
Example:
See
Example "Generating an RF envelope signal and defining
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:BIAS
<Bias>
Sets a bias.
Parameters:
<Bias>
float
Range:
-4 to 4
Increment: 1E-4
*RST:
0
Example:
See
Example "Generating an RF envelope signal and defining
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:OFFSet
<Offset>
Sets an offset between the envelope and the inverted envelope signal.
Parameters:
<Offset>
float
Range:
-4 to 4
Increment: 1E-4
*RST:
0
Default unit: mV
Example:
See
Example "Generating an RF envelope signal and defining
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:VPP[:MAX]
<VppMax>
Set the maximum value of the driving voltage V
pp
of the used external DC modulator.