Remote Control Commands
R&S
®
SGT100A
364
User Manual 1176.8674.02 ─ 07
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PATTern
<Pattern>
The command defines the bit pattern used to generate the marker signal in the setting
SOURce:BB:ARB:TRIGger:OUTPut:MODE PATTern
0 is marker off, 1 is marker on.
Parameters:
<Pattern>
<32 bits pattern>
*RST:
0
Example:
BB:ARB:TRIG:OUTP2:PATT #H39FE0000,32
sets a bit pattern.
BB:ARB:TRIG:OUTP2:MODE PATT
activates the marker signal according to a bit pattern on output
MARKER 2.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PULSe:DIVider
<Divider>
The command sets the divider for the pulsed marker signal in the setting
SOURce:BB:ARB:TRIGger:OUTPut:MODE PULSe
. The pulse frequency is derived
by dividing the symbol rate by the divider.
Parameters:
<Divider>
integer
Range:
2 to 1024
*RST:
2
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PULSe:FREQuency?
The command queries the pulse frequency of the pulsed marker signal in the setting
SOURce:BB:ARB:TRIGger:OUTPut:MODE PULSe
. The pulse frequency is derived
by dividing the symbol rate by the divider. The divider is defined with com-
mand
:BB:ARB:TRIG:OUTP:PULS:DIV
.
Return values:
<Frequency>
float
Increment: 0.001
Example:
BB:ARB:TRIG:OUTP2:PULS:DIV 4
sets the divider for the marker signal on the output to the value
4.
BB:ARB:TRIG:OUTP2:MODE PULS
enables the pulsed marker signal.
BB:ARB:TRIG:OUTP2:PULS:FREQ?
queries the pulse frequency of the marker signal.
Response: 33 000
the resulting pulse frequency is 33 kHz.
Usage:
Query only
SOURce Subsystem