![R&S RTO6 Скачать руководство пользователя страница 709](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_3064646709.webp)
Protocol analysis
R&S
®
RTO6
709
User Manual 1801.6687.02 ─ 05
"Label Min"
Defines the bit pattern of the label.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor"
"Label Max"
The second label pattern is required to specify a range with condi-
tions "In range" and "Out of range".
Remote command:
TRIGger<m>:ARINc:LABel:CONDition
Data setup: Condition, Data Min, Data Max ← Label + Data
The data setup consists of the condition and one or two data patterns.
"Condition"
Defines the operator to set a specific data ("Equal" or "Not equal") or
a data range.
"Data Min"
Defines the bit pattern of the data.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor"
"Data Max"
The second data pattern is required to specify a range with conditions
"In range" and "Out of range".
Remote command:
TRIGger<m>:ARINc:DATA:CONDition
SDI / SSM ← Label + Data
Sets the values for the source/destination identifier (SDI) and the sign/status matrix
(SSM) bits.
Remote command:
Error Conditions
Specifies the error conditions to be triggered on.
Coding error ← Error Conditions
Triggers on a coding error.
Remote command:
Parity Error ← Error Conditions
Checks the parity and triggers if the parity is even.
Remote command:
ARINC 429 (option R&S
RTO6-K530)