Remote control commands
R&S
®
RTO6
2343
User Manual 1801.6687.02 ─ 05
Parameters:
<GlitchError>
ON | OFF
*RST:
OFF
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:EBTB:STYPe
<SearchName>,<Type>
SEARch:TRIGger:EBTB:STYPe?
<SearchName>
Selects the search type.
Parameters:
<Type>
KD | EB | TB | EXPRession | ERRor
KD
: K/D symbol
EB
: 8-bit pattern
TB
: 10-bit pattern
*RST:
KD
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:EBTB:SYME
<SearchName>,<Expression>
SEARch:TRIGger:EBTB:SYME?
<SearchName>
Selects the format of the symbol to be searched for, if
is set to
EXPRession
.
Parameters:
<Expression>
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:EBTB:SYMType
<SearchName>,<SymbolType>
SEARch:TRIGger:EBTB:SYMType?
<SearchName>
Selects the data character (Dx.y) or control character to bea searched for. You can
specify he value of the data character to be searched for with
Parameters:
<SymbolType>
DXY | K280 | K281 | K282 | K283 | K284 | K285 | K286 | K287 |
K237 | K277 | K297 | K307
*RST:
K285
Parameters for setting and query:
<SearchName>
Protocols