![R&S RTO6 Скачать руководство пользователя страница 2022](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_30646462022.webp)
Remote control commands
R&S
®
RTO6
2022
User Manual 1801.6687.02 ─ 05
TRIGger<m>:ETHernet:FRAMe:CMAX
<CRCPatternMax>
Sets the end value of the frame check sequence range, if
is set to
INRange
or
OORange
.
Suffix:
<m>
.
1..3
Parameters:
<CRCPatternMax>
TRIGger<m>:ETHernet:FRAMe:CMIN
<CRCPatternMin>
Specifies a CRC pattern, or sets the start value of a pattern range.
Suffix:
<m>
.
1..3
Parameters:
<CRCPatternMin>
TRIGger<m>:ETHernet:FRAMe:DCONdition
<DestAddrOptor>
Sets the destination address operator to trigger on a specific pattern or a range.
Suffix:
<m>
.
1..3
Parameters:
<DestAddrOptor>
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less than or equal, Greater Than,
Greater than or equal. These conditions require a destination
address to be set with
TRIGger<m>:ETHernet:FRAMe:DMIN
.
INRange | OORange
In range, Out of range. Set the minimum and maximum value of
the range with
TRIGger<m>:ETHernet:FRAMe:DMIN
and
TRIGger<m>:ETHernet:FRAMe:DMAX
*RST:
EQUal
TRIGger<m>:ETHernet:FRAMe:DMAX
<DestAddrPattMax>
Sets the end value of a destination address range, if
is set to
INRange
or
OORange
.
Suffix:
<m>
.
1..3
Parameters:
<DestAddrPattMax>
Protocols