R&S RTC1002 Скачать руководство пользователя страница 1

R&S

®

RTC1000

Digital Oscilloscope

Getting Started

1335734602
Version 06

 

(=S×^2)

Sie haben Fragen oder wünschen eine Beratung? 

Angebotsanfrage unter

 

+49 

7121 / 51 50 50

 oder über 

info@datatec.

eu

Distributed by:

Содержание RTC1002

Страница 1: ...R S RTC1000 Digital Oscilloscope Getting Started 1335734602 Version 06 S 2 Sie haben Fragen oder wünschen eine Beratung Angebotsanfrage unter 49 7121 51 50 50 oder über info datatec eu Distributed by ...

Страница 2: ...fo rohde schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the owners 1335 7346 02 Version 06 R S RTC1000 Throughout this manual products from Rohde Schwarz are indicated without the symbol e g R S RTC1000 is indicated as R S RTC1000 ...

Страница 3: ... 4 Release Notes Open Source Acknowledgment 8 3 Preparing for Use 9 3 1 Unpacking and Checking the Instrument 9 3 2 Positioning the Instrument 10 3 3 Starting the Instrument 11 3 3 1 Powering On 11 3 3 2 Starting Up and Shutting Down 12 3 3 3 Powering Off 13 3 3 4 EMI Suppression 13 3 4 Replacing the Fuse 13 4 Instrument Tour 15 4 1 Front Panel 15 4 1 1 Input Connectors 16 4 1 2 Other Connectors o...

Страница 4: ...Contents R S RTC1000 4 Getting Started 1335 7346 02 06 ...

Страница 5: ...documentation It warns you about the potential dangers and gives instructions how to prevent personal injury or dam age caused by dangerous situations Safety information is provided as follows The Basic Safety Instructions in different languages are delivered as a prin ted brochure with the instrument Throughout the documentation safety instructions are provided when you need to take care during s...

Страница 6: ... the data sheet Note that the general safety instructions also contain information on operating conditions Position the instrument as described in the following sections Make sure that all fan openings are unobstructed and the airflow perforations are unimpeded The minimum distance from the wall is 10 cm Signal levels at the input connectors are all within the specified ranges Signal outputs are c...

Страница 7: ...mote control a complete description of the remote control commands with programming examples and information on maintenance and instrument interfaces Includes the contents of the getting started manual The online version of the user manual provides the complete contents for immedi ate display on the internet Instrument help The help offers quick context sensitive access to the functional descripti...

Страница 8: ...s and optional accessories The brochure provides an overview of the instrument and deals with the specific characteristics See www rohde schwarz com brochure datasheet rtc1000 2 3 Calibration Certificate The document is available on https gloris rohde schwarz com calcert You need the device ID of your instrument which you can find on a label on the rear panel 2 4 Release Notes Open Source Acknowle...

Страница 9: ...damage If there is damage or anything is missing immediately contact the carrier as well as your distributor Make sure not to discard the box and packing mate rial Packing material Retain the original packing material If the instrument needs to be transpor ted or shipped later you can use the material to protect the control elements and connectors Delivery contents The delivery package contains th...

Страница 10: ...ck mount using a rack mount kit The order number of the rack mount kit is given in the data sheet The installation instructions are part of the rack mount kit Risk of injury if feet are folded out The feet can fold in if they are not folded out completely or if the instrument is shifted This can cause damage or injury Fold the feet completely in or out to ensure stability of the instrument Never s...

Страница 11: ...ments do not draw in the preheated air from their neighbors When mounting the instrument in a rack observe the instructions of the rack manufacturer to ensure sufficient airflow and avoid overheating 3 3 Starting the Instrument 3 3 1 Powering On The R S RTC1000 can be used with different AC power voltages and adapts itself automatically to it The nominal ranges are 100 V to 240 V AC at 50 Hz to 60...

Страница 12: ...er switch on the rear panel is in position I 2 Press the ON OFF key The key is located next to the upper right corner of the screen The instrument performs a system check and starts the firmware If the previ ous session was terminated regularly the oscilloscope uses the last settings Table 3 1 Colors of the ON OFF key Unlit Instrument is on firmware is working Red Standby instrument is off main po...

Страница 13: ...necting the power cord the instrument loses its current settings Fur thermore program data can be lost Press the ON OFF key first to shut down the application properly 3 3 4 EMI Suppression Electromagnetic interference EMI may affect the measurement results To suppress generated electromagnetic interference EMI Use suitable shielded cables of high quality For example use double shielded RF and LAN...

Страница 14: ...lectric shock Before opening the fuse holder make sure that the instrument is switched off and disconnected from all power supplies Always use fuses supplied by Rohde Schwarz as spare parts or fuses of the same type and rating 1 Pull the fuse holder out of its slot on the rear panel 2 Exchange the fuse 3 Insert the fuse holder carefully back in its slot until it latches Replacing the Fuse ...

Страница 15: ...tional blocks to the right of the display Figure 4 1 Front view of the R S RTC1000 1 Display 2 Softkeys and menu 3 ON OFF key 4 Cursor Menu Analyze and General sections 5 Vertical Trigger and Horizontal sections 6 BNC connectors of the analog channel inputs 7 BNC connector of the external trigger input 8 Pattern generator output option R S RTC B6 and probe adjustment output Front Panel ...

Страница 16: ...s is 1 MΩ Risk of electrical shock maximum input voltages The maximum input voltage on channel inputs must not exceed 200 V peak and 150 V RMS For the external trigger input the maximum input voltage is 100 V peak and 70 V RMS Transient overvoltages must not exceed 200 V peak Voltages higher than 30 V RMS or 42 V peak or 60 V DC are regarded as hazardous contact voltages When working with hazardou...

Страница 17: ... probe manufacturer Explanation According to section AA 2 4 of EN 61010 2 030 measuring circuits without any measurement category are intended for measurements on circuits which are not directly connected to the mains Logic probe 9 The connector for logic channels can be used if the Mixed Signal Option R S RTC B1 is installed The option provides a logical probe with 8 digital chan nels D0 to D7 Th...

Страница 18: ...ti purpose BNC output that can function as pass fail and trigger output output for component testing and as function generator output with option R S RTC B6 USB type A 11 USB 2 0 type A interface to connect a USB flash drive for storing and reloading instrument settings and measurement data and to update the firmware 4 2 Rear Panel Figure 4 2 shows the rear panel of the R S RTC1000 with its connec...

Страница 19: ...tch 1 The instrument supports a wide range power supply It automatically adjusts to the correct range for the applied voltage There is no line voltage selector The AC main power switch disconnects the instrument from the AC power line USB type B 2 USB 2 0 interface of type B device USB to connect a printer or for remote con trol of the instrument Note Electromagnetic interference EMI can affect th...

Страница 20: ...Instrument Tour R S RTC1000 20 Getting Started 1335 7346 02 06 LAN 3 8 pin connector RJ 45 used to connect the instrument to a Local Area Network LAN It supports up to 100 Mbit s Rear Panel ...

Страница 21: ...rovides support and works with you to find a solution to your query on any aspect of the operation program ming or applications of Rohde Schwarz products Contact information Contact our customer support center at www rohde schwarz com support or fol low this QR code Figure 5 1 QR code to the Rohde Schwarz support page Sie haben Fragen oder wünschen eine Beratung Angebotsanfrage unter 49 7121 51 50...

Отзывы: