Remote control commands
R&S
®
RTA4000
465
User Manual 1335.7898.02 ─ 08
TRIGger:B:MODE
<Mode>
Sets a time delay or event delay for the B-trigger. The instrument waits for that delay
after an A-trigger until it recognizes the B-trigger.
Parameters:
<Mode>
DELay | EVENts
DELay
Time delay. Set the time with
.
EVENts
Event delay. Set the number of events with
*RST:
DELay
TRIGger:B:DELay
<DelayTime>
Sets the time the instrument waits until it checks the B-trigger condition.
Parameters:
<DelayTime>
Range:
20e-9 to 6,871946854
Increment: Depends on the <DelayTime> value. The longer the
time, the higher the increment.
*RST:
20e-9
Default unit: s
TRIGger:B:EVENt:COUNt
EventCount
Sets a number of B-trigger events that fulfill the B-trigger condition but do not cause
the trigger. The oscilloscope triggers on the n-th event, the last of the specified number
of events.
Parameters:
EventCount
Range:
1 to 65535
Increment: 1
*RST:
1
17.5.4
Width trigger
To set the trigger level (threshold), use:
●
●
CHANnel<m>:THReshold:FINDlevel
●
CHANnel<m>:THReshold:HYSTeresis
Trigger