Remote Control Commands
R&S
®
NGL200/NGM200
141
User Manual 1178.8736.02 ─ 06
Example:
INST:NSEL 1
BATT:SIM:VOC:FULL?
Returns 1 if channel 1 battery simulator is fully charge.
Usage:
Query only
BATTery:SIMulator[:ENABle]
<arg0>
Enables, disables or queries the specific channel of the battery simulator state.
Parameters:
<arg0>
1 | 0
Example:
INST:NSEL 1
BATT:SIM 1
Enables the battery simulator state for channel 1.
BATTery:STATus?
Queries the status of the battery (idle, charging or discharging).
Example:
INST:NSEL 1
BATT:STAT?
Returns the status of the battery state from channel 1.
Usage:
Query only
BATTery:MODel:CAPacity
<arg0>
Sets or queries the battery model capacity.
Parameters:
<arg0>
Sets the battery model capacity.
Example:
INST:NSEL 1
BATT:MODel:CAP 50
Sets battery model capacity as 50 % for channel 1.
BATTery:MODel:CLEar
Clears the current battery model.
Example:
INST:NSEL 1
BATT:MOD:CLE
Clear the current battery model for channel 1.
Usage:
Event
BATTery:MODel:DATA
{<arg0>, <arg1>, <arg2>}...
Sets or queries the battery model data.
Advanced Operating Commands