Table 5.8 shows the state transitions and the events causing the state transition:
Table 5.8 State Transitions (Events)
Table 5.9 State Transitions (Rebroadcast)
No.
Old State
New State
Event
1
Idle
Connecting
Connection establishment pending.
2
Connecting
ConnectedTx Connection established.
3
Connecting
Idle
Connection request failed, e.g. destination not reachable.
4
Connecting
Busy
Other station won competition for connection (other station
tries to set up a connection to a 2
nd
other station).
5
ConnectedTx
Disconnecting
Connection termination initiated by user.
6
Disconnecting
Idle
Connection termination finished.
7
ConnectedTx
Idle
Idle timeout.
8
Idle
Busy
•
External connection established.
•
External FastLink data transmission detected.
9
Busy
Idle
•
External connection termination.
•
Idle timeout.
10
Idle
ConnectedRx Connection
established.
11
ConnectedRx
Idle
•
Connection termination (initiated by active Tx station).
•
Idle timeout.
12
Connecting
ConnectedRx
Other station won competition for connection (other station
tries to set up a connection to this radio).
No.
Old State
New State
Event
100
Connecting
Rebro-Connecting
Connection establishment over rebroadcast pend-
ing .
101
Rebro-Connecting
Rebro-Busy
A remote network in rebroadcast scenario is busy.
102
Rebro-Connecting
ConnectedTx
Connection over rebroadcast established.
103
Rebro-Connecting
Idle
Connection request failed, e.g. destination not
reachable.
104
Connecting
Rebro-Busy
Remote network in rebroadcast scenario is busy.
The Rebro-Busy state indicates that the connection
request failed due to a busy remote network (and not
due to a non-reachable station).
This transition is followed immediately by the next
transition (105).
105
Rebro-Busy
Idle
Remote network in rebroadcast scenario is busy.
Содержание M3SR 4100 Series
Страница 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Страница 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Страница 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Страница 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Страница 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Страница 546: ...M3SR Series 4100 Further Settings are Relevant for SECOM H Operation 4 210 Operating Manual 6175 4760 02 01...
Страница 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Страница 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Страница 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...