Remote commands to perform measurements in MSRA mode
R&S
®
FSWP-B1
112
User Manual 1177.5862.02 ─ 09
For details on the common R&S
FSWP status registers refer to the description of
remote control basics in the R&S
FSWP User Manual.
*RST does not influence the status registers.
.................................................................................. 112
Commands to query the STATus:OPERation register
...........................................113
9.7.1
STATus:OPERation register
The
STATus:OPERation
register contains information on current activities of the
R&S
FSWP. It also contains information on activities that have been executed since
the last read out.
You can read out the register with
Table 9-3: Meaning of the bits used in the STATus:OPERation register
Bit No.
Meaning
0
CALibrating
This bit is set as long as the instrument is performing a calibration.
1-2
Not used
3
SWEeping
Sweep is being performed in base unit (applications are not considered); identical to bit 4
Available in the optional Spectrum application.
4
MEASuring
Measurement is being performed in base unit (applications are not considered); identical to bit 3
Available in the optional Spectrum application.
5
Waiting for TRIgger
Instrument is ready to trigger and waiting for trigger signal.
Available in the optional Spectrum application.
6-7
Not used
8
HardCOPy
in progress
This bit is set while the instrument is printing a hardcopy.
9
Not used
10
Range completed
This bit is set when a range in the sweep list has been completed if "Stop after Range" has
been activated.
Available in the optional Spectrum application.
11-14
Not used
15
This bit is always 0.