Network and Remote Operation
R&S
®
FSW
783
User Manual 1173.9411.02 ─ 43
# python script created by FSW: 29:11:2017 09:08:53
import visa
# connect to instrument (MU717225)
VisaResourceManager = visa.ResourceManager()
FSW = VisaResourceManager.open_resource("TCPIP::10.124.0.195::INSTR")
# Display update ON
FSW.write("SYST:DISP:UPD ON")
FSW.write("*RST")
FSW.write("INIT:CONT OFF")
FSW.write("SENS:FREQ:CENT 850000000")
FSW.write("SENS:FREQ:SPAN 4000000")
FSW.write("DISP:WIND:SUBW:TRAC:Y:SCAL:RLEV 10")
FSW.write("CALC:MARK:FUNC:POW:SEL ACP")
FSW.write("CALC:MARK:FUNC:POW:PRES S2CD")
FSW.write("SENS:ADJ:LEV;*WAI")
FSW.write("SENS:POW:HSP ON")
FSW.write("TRAC1:DATA? TRACE1")
FSW.query("CALC1:MARK:Y?")
FSW.write("CALC1:MARK:FUNC:POW:RES? CPOW")
# Back to local mode
FSW.write("@LOC")
13.5
Network and Remote Control Settings
Access
: [SETUP] > "N Remote"
Network settings in secure user mode
Be sure to store all network settings before
is enabled; see
ter 5.1.7, "Protecting Data Using the Secure User Mode"
If the currently stored network settings are not suitable, you must correct them each
time you switch on the R&S
FSW in secure user mode, as the settings are not stored
permanently in this case.
The remote commands required to define these settings are described in
ter 14.10.7, "Configuring the Network and Remote Control"
Step-by-step instructions are provided in
Chapter 13.6, "How to Set Up a Network and
..................................................................................... 784
............................................................................................789
Network and Remote Control Settings
Содержание FSW Series
Страница 1: ...R S FSW Signal and Spectrum Analyzer User Manual User Manual Version 43 1173941102 2...
Страница 16: ...Contents R S FSW 16 User Manual 1173 9411 02 43...
Страница 1388: ...Maintenance R S FSW 1388 User Manual 1173 9411 02 43 c If necessary remove any excess moisture with a dry soft cloth Cleaning...