[SENSe:]ADEMod<n>:PM:RPOint[:X]
<Time>
This command determines the position where the phase of the PM-demodulated signal
is set to 0 rad. The maximum possible value depends on the measurement time
selected in the instrument; this value is output in response to the query
ADEM:PM:RPO:X? MAX
.
Suffix:
<n>
.
irrelevant
Parameters:
<Time>
0 s to measurement time
*RST:
0 s
Example:
ADEM:PM:RPO 500us
Sets the position where the phase to 0 rad setting to 500 µs.
Manual operation:
See
"Zero Phase Reference Position (PM Time Domain only)"
[SENSe:]ADEMod<n>:SQUelch[:STATe]
<State>
This command activates the squelch function, i.e. if the signal falls below a defined
threshold (see
[SENSe:]ADEMod<n>:SQUelch:LEVel
lated data is automatically set to 0.
Suffix:
<n>
.
irrelevant
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
0
Example:
DEM:SQU ON
Signals below the level threshold are squelched.
Manual operation:
See
[SENSe:]ADEMod<n>:SQUelch:LEVel
<Threshold>
This command defines the level threshold below which the demodulated data is set to
0 if squelching is enabled (see
[SENSe:]ADEMod<n>:SQUelch[:STATe]
Suffix:
<n>
.
irrelevant
Parameters:
<Threshold>
numeric value
The absolute threshold level
Range:
-150 dBm to 30 dBm
*RST:
-40 dBm
Configuring the Measurement