Remote Commands to Perform Measurements with I/Q Data
R&S
®
FSV/A3000 I/Q
Analyzer
176
User Manual 1178.8536.02 ─ 01
LDIStortion
Optimized for low distortion by avoiding intermodulation
*RST:
LDIStortion
Example:
INP:ATT:AUTO:MODE LNO
INPut<ip>:EATT
<Attenuation>
This command defines an electronic attenuation manually. Automatic mode must be
switched off (
INP:EATT:AUTO OFF
, see
If the current reference level is not compatible with an attenuation that has been set
manually, the command also adjusts the reference level.
This command requires the electronic attenuation hardware option.
It is not available if the optional Digital Baseband Interface is active.
Suffix:
<ip>
.
1 | 2
irrelevant
Parameters:
<Attenuation>
attenuation in dB
Range:
see data sheet
Increment: 1 dB
*RST:
0 dB (OFF)
Default unit: DB
Example:
INP:EATT:AUTO OFF
INP:EATT 10 dB
Manual operation:
See
" Using Electronic Attenuation "
INPut<ip>:EATT:AUTO
<State>
This command turns automatic selection of the electronic attenuation on and off.
If on, electronic attenuation reduces the mechanical attenuation whenever possible.
This command requires the electronic attenuation hardware option.
It is not available if the optional Digital Baseband Interface is active.
Suffix:
<ip>
.
1 | 2
irrelevant
Parameters:
<State>
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
*RST:
1
Configuring I/Q Analyzer Measurements