Remote Commands for Bluetooth Measurements (K8)
R&S
®
FSV-K8
88
Operating Manual 1176.7610.02 ─ 02
Return values:
<Result>
0
PASS
1
FAIL
Example:
INST:SEL BTO
Activates the Bluetooth Measurements option
INIT:CONT OFF
Selects single sweep operation
CONF:BTO:MEAS OPOW
Activates Output Power measurement
INIT;*WAI
Starts the measurement with synchronization
CALC:BTO:STAT?
Queries the status
Usage:
Query only
Mode:
BT
4.1.2 CALCulate:DELTamarker Subsystem (BLUETOOTH, K8)
CALCulate<n>:DELTamarker<m>:Y?
.................................................................................88
CALCulate<n>:DELTamarker<m>:Y?
This command queries the measured value of a delta marker. The corresponding delta
marker is activated, if necessary. The output is always a relative value referred to
marker 1 or to the reference position (reference fixed active).
To obtain a correct query result, a complete sweep with synchronization to the sweep
end must be performed between the activation of the delta marker and the query of the
y value. This is only possible in single sweep mode.
Depending on the unit defined with
CALC:UNIT:POW
or on the activated measuring
functions, the query result is output in the units below:
Table 4-1: Bluetooth measurements
Parameter, measuring function or result display
Output unit
OUTPUT POWER result display (R&S
FSV–K8)
dB
TX SPECTRUM ACP result display (R&S
FSV–K8)
dB
MODULATION CHARACTERISTICS result display
(R&S
FSV–K8)
Hz
INITIAL CARR FREQ TOL result display (R&S
FSV–K8)
Hz
CARRIER FREQ DRIFT result display (R&S
FSV–K8)
Hz
RELATIVE TX POWER (R&S
FSV–K8)
dB
IN–BAND SPURIOUS EMISSIONS (R&S
FSV–K8)
dB
CALCulate subsystem