Remote Commands for Bluetooth Measurements (K8)
R&S
®
FSV-K8
114
Operating Manual 1176.7610.02 ─ 02
Parameters:
<Bandwidth>
refer to data sheet
*RST:
(AUTO is set to ON)
Example:
BAND 1 MHz
Sets the resolution bandwidth to 1 MHz
[SENSe:]BANDwidth|BWIDth[:RESolution]:AUTO
<State>
This command couples and decouples the resolution bandwidth to the span.
The automatic coupling adapts the resolution bandwidth to the current frequency span
according to the relationship between frequency span and resolution bandwidth.
The 6 dB bandwidths 200 Hz, 9 kHz and 120 kHz and the channel filters available are
not set by the automatic coupling.
Use
to define the ratio
RBW/span.
Parameters:
<State>
ON | OFF
*RST:
ON
Example:
BAND:AUTO OFF
Switches off the coupling of the resolution bandwidth to the
span.
[SENSe:]BANDwidth|BWIDth[:RESolution]:RATio
<Ratio>
This command defines the ratio between the resolution bandwidth (Hz) and the span
(Hz).
Note that the ratio defined with the remote command (RBW/span) is reciprocal to that
of the manual operation (span/RBW).
Parameters:
<Ratio>
Range:
0.0001 to 1
*RST:
0.01
Example:
BAND:RAT 0.01
[SENSe:]BANDwidth|BWIDth[:RESolution]:TYPE
<FilterType>
This command selects the type of resolution filter.
For detailed information on filters see
chapter 3.10.1, "Selecting the Appropriate Filter
, on page 64 and
chapter 3.10.2, "List of Available RRC and Channel Filters"
When changing the filter type, the next larger filter bandwidth is selected if the same
filter bandwidth is not available for the new filter type.
5 Pole filters are not available when using the sweep type "FFT".
SENSe Subsystem (BLUETOOTH, K8)