Remote Control Commands - R&S
FSV-K70
R&S
®
FSV-K70
323
Operating Manual 1176.7578.02 ─ 09
Setting parameters:
<Enable>
0
the EVENt bit is not set
1
the EVENt bit is set
Usage:
Query only
SCPI confirmed
Mode:
VSA
STATus:QUEStionable:MODulation<n>:<ResultType>:PTRansition?
<Mode>
This bit acts as a transition filter. When a bit of the
CONDition
part of the associated
status register for the result type is changed from 0 to 1, the
PTR
bit decides whether
the
EVENt
bit is set to 1.
Suffix:
<n>
.
1..4
<ResultType>
CFRequency | EVM | FSK | IQRHo | MAGNitude | PHASe
CFRequency = limit violations in Carrier Frequency evaluation
EVM = limit violations in EVM evaluation
FSK = limit violations in FSK evaluation
IQRHo = limit violations in I/Q-Offset and RHO evaluation
MAGNitude = limit violations in Magnitude Error evaluation
PHASe = limit violations in Phase Error evaluation
Setting parameters:
<Enable>
0
the EVENt bit is not set
1
the EVENt bit is set
Usage:
Query only
SCPI confirmed
Mode:
VSA
STATus:QUEStionable:SYNC:CONDition?
<ChannelName>
This command reads out the CONDition section of the status register.
The command does not delete the contents of the EVENt section.
Query parameters:
<ChannelName>
String containing the name of the channel.
The parameter is optional. If you omit it, the command works for
the currently active channel.
Usage:
Query only
STATus:QUEStionable Subsystem
Содержание FSV-K70
Страница 368: ...Formulae and Abbreviations R S FSV K70 368 Operating Manual 1176 7578 02 09 Formulae ...
Страница 370: ...Formulae and Abbreviations R S FSV K70 370 Operating Manual 1176 7578 02 09 Formulae ...
Страница 371: ...Formulae and Abbreviations R S FSV K70 371 Operating Manual 1176 7578 02 09 Formulae ...
Страница 372: ...Formulae and Abbreviations R S FSV K70 372 Operating Manual 1176 7578 02 09 Formulae ...