Brief Description of Vector Signal Analysis
R&S
®
FSV-K70
19
Operating Manual 1176.7578.02 ─ 09
Predefined measurement filters
The most frequently required measurement filters are provided by the R&S
FSV-K70.
Table 2-4: Overview of predefined measurement filters
EDGE NSR
Measurement filter required for the "EDGE, Normal Symbol
Rate" standard. (see 3GPP TS 45.005, chapter 4.6 Modulation
Accuracy). The resulting system is NOT inter-symbol interfer-
ence free.
EDGE HSR (Narrow Pulse)
Measurement filter required for the "EDGE, High Symbol Rate,
Narrow Pulse" standard.
EDGE HSR (Wide Pulse)
Measurement filter required for the "EDGE, High Symbol Rate,
Wide Pulse" standard.
Gauss
Classic Gauss filter with an adjustable BT
Low ISI Meas Filter
Measurement filter implemented to retain a low intersymbol
inferference. Best suited for eye diagrams or I/Q vector dia-
grams. Not necessarily suited for EVM evaluation due to amplifi-
cation in the pass band.
Low Pass (Narrow)
Pass band up to F
symbol
/2
Stop band starts at F
symbol
(-40dB)
Low Pass (Wide)
Pass band up to F
symbol
Stop band starts at 1.5*F
symbol
(-40dB)
Rectangular
Rectangular filter in the time domain with a length of 1 symbol
period; integrate and dump effect
RRC
Root Raised Cosine Filter. The roll-off parameter "Alpha" is set
according to the Transmit filter if the "Auto (according to Trans-
mit filter)" option is enabled (see
wise it must be set manually.
If the Transmit filter is also a Root Raised Cosine filter with the
same roll-off parameter, the resulting system is inter-symbol
interference free.
USER
User-defined filter.
Define the filter using the
For details see
Chapter 2.2.7, "Customized Filters"
NONE
No measurement filter is used.
The frequency response of the available standard-specific measurement filters is
shown in
Chapter A.1.6.2, "Measurement Filter"
2.2.7 Customized Filters
The analytical filter types RC (raised cosine), RRC (root-raised cosine) and GAUS-
SIAN as well as the most important standard-specific filters are already integrated in
the R&S
FSV-K70. In addition, it is possible to use user-defined measurement and
Transmit filters. Customized filters may be useful for the following purposes:
Filters and Bandwidths During Signal Processing
Содержание FSV-K70
Страница 368: ...Formulae and Abbreviations R S FSV K70 368 Operating Manual 1176 7578 02 09 Formulae ...
Страница 370: ...Formulae and Abbreviations R S FSV K70 370 Operating Manual 1176 7578 02 09 Formulae ...
Страница 371: ...Formulae and Abbreviations R S FSV K70 371 Operating Manual 1176 7578 02 09 Formulae ...
Страница 372: ...Formulae and Abbreviations R S FSV K70 372 Operating Manual 1176 7578 02 09 Formulae ...