Instrument Functions for Vector Signal Analysis
R&S
®
FSV-K70
127
Operating Manual 1176.7578.02 ─ 09
The signal description of the expected input signal determines the available configura-
tion settings and the available burst or pattern settings. You can define a pattern to
which the result range can be aligned (see
A schematic preview of the current signal description is displayed in the preview area
at the bottom of the dialog box. The preview area is not editable directly.
The "Modulation" tab contains modulation and Transmit filter settings. A live preview of
the Constellation I/Q trace using the currently defined settings is displayed at the bot-
tom of the dialog box to visualize the changes to the settings.
For details on the available settings see
on page 143 and
Frontend
Displays the "Frontend" tab of the "Frontend & I/Q Capture Settings" dialog box.
A live preview of the signal with the current settings is displayed in the preview area at
the bottom of the dialog box. The preview area is not editable directly.
Note that this works only in continuous sweep mode.
For details on the available settings see
I/Q Capture
Displays the "I/Q Capture" tab of the "Frontend & I/Q Capture Settings" dialog box.
A live preview of the signal in the capture buffer with the current settings is displayed in
the preview area at the bottom of the dialog box. The preview area is not editable
directly.
Note that this works only in continuous sweep mode.
For details on the available settings see
Config Pattern
Displays the "Advanced Pattern Settings" dialog box (see
Burst/Pattern Search
Displays the "Burst/Pattern Search" dialog box.
The "Burst Search" tab contains the settings for burst searches.
A live preview of the capture buffer with the current settings is displayed in the preview
area at the bottom of the dialog box. The green bar below the trace indicates the
defined evaluation ranges (see
on page 167). The preview area is
not editable directly.
The "Pattern Search" tab contains the settings for pattern searches.
For details on the available settings see
Range Settings
Displays the "Result Range" tab of the "Result Range/Evaluation Range" dialog box.
A preview of the result display with the current settings is displayed in the visualization
area at the bottom of the dialog box.
Softkeys and Menu Overview for Vector Signal Analysis (R&S
FSV-K70)
Содержание FSV-K70
Страница 368: ...Formulae and Abbreviations R S FSV K70 368 Operating Manual 1176 7578 02 09 Formulae ...
Страница 370: ...Formulae and Abbreviations R S FSV K70 370 Operating Manual 1176 7578 02 09 Formulae ...
Страница 371: ...Formulae and Abbreviations R S FSV K70 371 Operating Manual 1176 7578 02 09 Formulae ...
Страница 372: ...Formulae and Abbreviations R S FSV K70 372 Operating Manual 1176 7578 02 09 Formulae ...