Remote Control
R&S
®
ESR
982
User Manual 1175.7068.02 ─ 12
Suffix:
<n>
.
1 | 2
window;
Channel and adjacent-channel power measurements: Only "1" is
allowed as a suffix for the window.
Spectrum Emission Mask and Spurious Emissions measure-
ments:
selects the window that is displayed in full size (if no suffix is
defined, "1" is used):
1: diagram/result list
2: marker table
<m>
1 | 2
selects the item in the window to be displayed in full size:
1: diagram
2: result list
Parameters:
<Size>
LARGe | SMALl
LARGe
Channel and adjacent-channel power measurements: diagram
in full screen.
Spectrum Emission Mask and Spurious Emissions measure-
ments: diagram or list in full screen, depending on the value of
the suffix.
SMALl
split screen (diagram and list and table)
*RST:
SMALl
Example:
DISP:SIZE LARG
Displays the measurement diagram in full screen size.
DISP:WIND1:SUBW2:SIZE LARG
Displays the result list in full screen size.
DISP:WIND2:SIZE LARG
Displays the marker table in full screen size.
Mode:
all
DISPlay[:WINDow<n>][:SUBWindow<m>]:SELect
This command selects which window (screen) is active for applications with more than
one measurement window. For measurements with additional subwindows (e.g. SEM,
ACLR), the subwindow can also be selected.
Suffix:
<n>
.
1...4
window; For applications that do not have more than 1 measure-
ment window, the suffix <n> is irrelevant.