Remote Control
R&S
®
ESR
1037
User Manual 1175.7068.02 ─ 12
length: 28800
number of periods: 3
gap: 3800 samples
Program
:TRACe1:IQ ON
trace:iq:set NORM,0,3200000,IFP,POS,0,228000
:TRIGger1:SEQuence:LEVel:IFPower -20
:TRACe1:IQ:EGATe ON
:TRACe1:IQ:EGATe:TYPE EDGE
:TRACe1:IQ:EGATe:LENGth 28800
:TRACe1:IQ:EGATe:NOF 3
:TRACe1:IQ:EGATe:GAP 3800
Result
Figure 11-14: Result: periodic power ramp levels
11.17.16
Usage of Four Spectrum Instances
As of R&S
ESR firmware version 1.50, you can open up to four tabs for spectrum
mode with the softkey "New Spectrum" in the "MODE" menu. The following remote
example shows how to set up four tabs with four different measurements on a WCDMA
signal.
REM ************************************************************************
Public Sub 4SpectrumTabs()
result$ = Space$(100)
'--------- R&S FSV default setting -----------------------------------------
CALL SetupStatusReg 'Set status registers
Remote Control – Programming Examples