![R&S CMW-KM5 Series Скачать руководство пользователя страница 186](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802186.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
186
User Manual 1173.9628.02 ─ 16
The subframes for CQI and PMI reporting are determined by the parameter "cqi-pmi-
ConfigIndex". This parameter is configurable. Via a mapping table, the "cqi-pmi-Config-
Index" determines the reporting period N
p
and the reporting offset N
OFFSET,CQI
.
The subframes for RI reporting are determined by the parameters "M
RI
" and "N
OFF-
SET,RI
". The LTE signaling application uses "M
RI
" = 1 and "N
OFFSET,RI
" = -1.
This means, that the subframes for RI reporting are located immediately before the
subframes for CQI/PMI reporting.
If you want to evaluate reports for PCC and SCC, the carriers must use different sub-
frames for reporting. The carrier configurations must not overlap. This is also important
for scheduling types with a DL configuration that reacts to the reports, for example
"Follow WB CQI".
Example, dual-carrier FDD, wrong configuration:
PCC: "cqi-pmi-ConfigIndex" = 3 means offset = 1, period = 5
SCC: "cqi-pmi-ConfigIndex" = 9 means offset = 2, period = 10
The following table shows the resulting configuration for two frames. There is a colli-
sion in subframe number 1, with CQI/PMI reporting for the PCC and RI reporting for
the SCC.
Subframe
no.
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
PCC
R
C
R
C
R
C
R
C
SCC
R
C
R
C
C = CQI/PMI reporting, R = RI reporting
Example, dual-carrier FDD, correct configuration:
PCC: "cqi-pmi-ConfigIndex" = 3 means offset = 1, period = 5
SCC: "cqi-pmi-ConfigIndex" = 5 means offset = 3, period = 5
The following table shows the resulting configuration. There is no collision.
Subframe no.
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
PCC
R
C
R
C
R
C
R
C
SCC
R
C
R
C
R
C
R
C
C = CQI/PMI reporting, R = RI reporting
2.4.14 UE Measurement Report Settings
This section configures the UE measurement report. The report is shown in the main
signaling view, see
chapter 2.4.1.3, "UE Measurement Report"
For enabling of neighbor cell measurements, see
chapter 2.4.11.1, "Neighbor Cell Set-
GUI Reference
深圳德标仪器
135-1095-0799