![R&S CMW-KM5 Series Скачать руководство пользователя страница 135](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802135.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
135
User Manual 1173.9628.02 ─ 16
2.4.8 Downlink Power Levels
This section defines power levels of physical downlink channels and physical downlink
signals.
The parameters in this section except the power offset PA can be changed in all main
connection states including "Connection Established".
For carrier aggregation scenarios you can configure different PCC and SCC settings.
For background information, see also
chapter 2.2.10, "Physical DL Channels and Sig-
Fig. 2-56: DL power levels
RS EPRE
Defines the Energy Per Resource Element (EPRE) of the Reference Signal (RS). The
RS EPRE corresponds to the DL power averaged over all resource elements carrying
cell-specific reference signals within one subcarrier (15 kHz).
Additionally the "Full Cell BW Power" resulting from the RS EPRE is displayed. It is
calculated assuming that the full DL cell bandwidth is used (all subcarriers) and all
power offsets equal 0 dB.
Remote command:
GUI Reference
135-1095-0799