1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
217
User Manual 1173.9511.02 ─ 11
2.6.10 Message Monitoring
The following commands configure the message forwarding to a Message Analyzer
host.
CONFigure:EVDO:SIGN<i>:MMONitor:ENABle
<Enable>
Enable/Disable Message Monitor
Parameters:
<Enable>
OFF | ON
*RST:
Off
Example:
See
Configuring Message Monitoring
Firmware/Software:
V3.0.10
Manual operation:
See
"Add 1xEV-DO Signaling to logging"
CONFigure:EVDO:SIGN<i>:MMONitor:IPADdress
<Index>
Select/get the target IP address for message monitoring (
). The IP addresses are centrally managed from the
"Setup" dialog.
Parameters:
<Index>
IP1 | IP2 | IP3
Return values:
<IPAddress>
Example:
See
Configuring Message Monitoring
Firmware/Software:
V3.0.10
Manual operation:
See
2.6.11 RX Measurement
The following commands control the RX Measurements ("PER", "Throughput", "Data")
and retrieve the results.
"1xEV-DO Signaling" parameters
All RX measurements are based on an application stream that is configured and initi-
ated by the "1xEV-DO Signaling" application. Hence, adequate configuration of the
"1xEV-DO Signaling" application is a prerequisite.
The commands described in this section are only the ones related to measurement
control, statistics, limits, and measurement results.
Enable and Disable Measurements
...................................................................... 218
............................................................................................218
.............................................................................................221
Command Reference
135-1095-0799