1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
205
User Manual 1173.9511.02 ─ 11
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS881 required for release B
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:SID
<SystemID>
Defines the 15-bit System ID that the R&S
CMW broadcasts on its forward 1xEV-DO
signal
Parameters:
<SystemID>
Range:
0 to 32767 (2^15 - 1)
*RST:
1
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
2.6.9.2
Access Network Properties
The following commands define general settings for the simulated access network.
CONFigure:EVDO:SIGN<i>:NETWork:PROPerty:CLDTime
............................................... 205
CONFigure:EVDO:SIGN<i>:NETWork:PROPerty:FPACtivity
.............................................. 205
CONFigure:EVDO:SIGN<i>:NETWork:PROPerty:IRAT
......................................................206
CONFigure:EVDO:SIGN<i>:NETWork:PROPerty:CLDTime
<CLDTime>
Defines the time in s after which a connection is considered to be lost.
Parameters:
<CLDTime>
Range:
2 s to 6 s
*RST:
2 s
Default unit: s
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:PROPerty:FPACtivity
<Activity>
Defines the percentage of forward packets that the R&S
CMW directs to the AT under
test.
Parameters:
<Activity>
Range:
0 % to 100 %
*RST:
100 %
Default unit: %
Command Reference