WCDMA Multi Evaluation Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
643
User Manual 1173.9657.02 ─ 11
CONFigure:WCDMa:MEAS<i>:MEValuation:RESult:RCDerror
<EnableRCDE>
Enables or disables the evaluation of results and shows or hides the Relative CDE
view in the multi evaluation measurement.
Parameters:
<EnableRCDE>
OFF | ON
OFF:
Do not evaluate results, hide the view
ON:
Evaluate results and show the view
*RST:
OFF
Firmware/Software:
V1.0.15.0
Manual operation:
See
3.5.3.3
Measurement Parameters
The following commands define general settings for the multi evaluation measurement.
CONFigure:WCDMa:MEAS<i>:MEValuation:TOUT
........................................................... 643
CONFigure:WCDMa:MEAS<i>:MEValuation:REPetition
.....................................................644
CONFigure:WCDMa:MEAS<i>:MEValuation:SCONdition
...................................................644
CONFigure:WCDMa:MEAS<i>:MEValuation:MOEXception
................................................ 644
CONFigure:WCDMa:MEAS<i>:TPC:CSELection
...............................................................645
CONFigure:WCDMa:MEAS<i>:MEValuation:MSCount
...................................................... 645
CONFigure:WCDMa:MEAS<i>:MEValuation:PSLot
........................................................... 645
CONFigure:WCDMa:MEAS<i>:MEValuation:SYNCh
......................................................... 646
CONFigure:WCDMa:MEAS<i>:MEValuation:TOUT
<Timeout>
Defines a timeout for the measurement. The timer is started when the measurement is
initiated via a
READ
or
INIT
command. It is not started if the measurement is initiated
manually (ON/OFF key or RESTART/STOP key).
When the measurement has completed the first measurement cycle (first single shot),
the statistical depth is reached and the timer is reset.
If the first measurement cycle has not been completed when the timer expires, the
measurement is stopped. The measurement state changes to
RDY
and the reliability
indicator is set to 1, indicating that a measurement timeout occurred. Still running
READ
,
FETCh
or
CALCulate
commands are completed, returning the available results.
At least for some results there are no values at all or the statistical depth has not been
reached.
A timeout of 0 s corresponds to an infinite measurement timeout.
Parameters:
<Timeout>
Default unit: s
Firmware/Software:
V2.0.10
Command Reference