WCDMA Signaling
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
522
User Manual 1173.9657.02 ─ 11
Firmware/Software:
V3.0.30
Options:
R&S CMW-KS401
CONFigure:WCDMa:SIGN<i>:ULLogging:REPetition
<Repetition>
Specifies the repetition mode of the measurement. The repetition mode specifies
whether the measurement is stopped after a single-shot or repeated continuously. Use
to define the number of sub-
frames to be measured per single shot.
See also: "Statistical Settings" in the R&S
CMW user manual, chapter "Remote Con-
trol"
Parameters:
<Repetition>
SINGleshot | CONTinuous
SINGleshot:
Single-shot measurement
CONTinuous:
Continuous measurement
*RST:
SING
Example:
See
Firmware/Software:
V3.0.30
Options:
R&S CMW-KS401
Manual operation:
See
CONFigure:WCDMa:SIGN<i>:ULLogging:MSFRames
<MeasSubframes>
Defines the number of subframes to be measured per measurement cycle (statistics
cycle).
Parameters:
<MeasSubframes>
Volume of measured consecutive UL HS-DPCCH/E-DPCCH/
DPCCH subframes
Range:
15 to 10E+3
*RST:
100
Example:
See
Firmware/Software:
V3.0.30
Options:
R&S CMW-KS401
Manual operation:
See
CONFigure:WCDMa:SIGN<i>:ULLogging:SSFN
<SFN>
Specifies the first system frame number for which the UL HS-DPCCH/E-DPCCH/
DPCCH information is displayed.
System frame number corresponds to the subframe number of the UL HS-DPCCH/E-
DPCCH/DPCCH.
Command Reference
深圳德标仪器
135-1095-0799