WCDMA Signaling
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
497
User Manual 1173.9657.02 ─ 11
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS401
CONFigure:WCDMa:SIGN<i>:HACK:REPetition
<Repetition>
Specifies the repetition mode of the measurement. The repetition mode specifies
whether the measurement is stopped after a single-shot or repeated continuously. Use
to determine the number of HSDPA
subframes to be measured per single shot.
See also: "Statistical Settings" in the R&S
CMW user manual, chapter "Remote Con-
trol"
Parameters:
<Repetition>
SINGleshot | CONTinuous
SINGleshot:
Single-shot measurement
CONTinuous:
Continuous measurement
*RST:
SING
Example:
See
Configuring the HSDPA ACK Measurement
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS401
Manual operation:
See
CONFigure:WCDMa:SIGN<i>:HACK:MSFRames
<MeasSubframes>
Defines the number of HSDPA subframes to be measured per measurement cycle
(statistics cycle).
Parameters:
<MeasSubframes>
Range:
100 to 1E+6
Increment: 100
*RST:
2000
Example:
See
Configuring the HSDPA ACK Measurement
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS401
Manual operation:
See
CONFigure:WCDMa:SIGN<i>:HACK:HARQ
<MonitoredHARQ>
Selects either a single H-ARQ process (numbered 0 to 7) to be monitored or specifies
that all processes are to be monitored.
Parameters:
<MonitoredHARQ>
ALL | H0 | H1 | H2 | H3 | H4 | H5 | H6 | H7
*RST:
ALL
Command Reference