WCDMA Signaling
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
195
User Manual 1173.9657.02 ─ 11
Fig. 2-85: Settings for cell reselection
S intrasearch
Sets threshold S
intrasearch
for intra frequency measurements and for the Hierarchical Cell
Structure (HCS) measurement rules.
Option R&S CMW-KS410 required.
Remote command:
S intersearch
Sets threshold S
intersearch
for inter-frequency measurements and for the HCS measure-
ment rules.
Option R&S CMW-KS410 required.
Remote command:
S searchrat GSM
Sets threshold S search
RAT m
used in inter-RAT measurement rules for RAT m = GSM.
Option R&S CMW-KS410 required.
Remote command:
Q qualmin
Sets minimum required quality level in the target cell.
Option R&S CMW-KS410 required.
Remote command:
Q rxlevmin
Sets minimum required RX level in the target UMTS cell.