Remote Control Commands
R&S
®
NRX
287
User Manual 1178.5566.02 ─ 07
CALCulate<Measurement>:PTPeak:DATA?
Queries the peak-to-peak distance (maximum to minimum) of the measured values.
Suffix:
<Measurement>
.
1 to 8
Measurement
Usage:
Query only
CALCulate<Measurement>:SDEViation:DATA?
Queries the standard deviation of all measured values. The standard deviation is cal-
culated and reset together with the mean value,
Suffix:
<Measurement>
.
1 to 8
Measurement
Usage:
Query only
13.6
Calculation Functions
Further information:
●
"Channel Calculation Function"
●
Chapter 13.3, "Addressing Measurements and Sensors"
13.6.1
Selecting a Calculation Function
CALCulate<Measurement>:MATH[:EXPRession]
[<expression>]
Selects a channel calculation function that processes the results of one or two power
sensors. The result of this calculation is made available as a measured value.
SENSn
is assigned as primary sensor,
SENSm
as secondary sensor.
Table 13-3: <expression> parameters for absolute power measurements
Channel calculation func-
tion
<expression>
Description
Single measurement
"(SENSn)"
Measured value of sensor
A, B, C or D
Sum
"(SENSn+SENSm)"
Sum of the values measured by sensor
n
and sensor
m
Difference
"(SENSn-SENSm)"
Difference between the measured values of
sensor
n and sensor
m
With n and m= 1, 2, 3, 4 or A, B, C, D
Calculation Functions
www.allice.de
Allice Messtechnik GmbH