Remote Control Commands
R&S
®
NRP18S-xx
107
User Manual 1178.3686.02 ─ 05
Example:
SYST:COMM:NETW:IPAD:GAT '192.168.10.254'
Sets
192.168.10.254
as IP address of the default gateway.
SYSTem:COMMunicate:NETWork:IPADdress:INFO?
Effective only for the R&S
NRP LAN power sensors.
Queries the network status information.
Usage:
Query only
SYSTem:COMMunicate:NETWork:IPADdress:MODE
<mode>
Effective only for the R&S
NRP LAN power sensors.
Sets whether the IP address is assigned automatically or manually.
Parameters:
<mode>
AUTO | STATic
AUTO
Assigns the IP address automatically, provided the network sup-
ports DHCP.
STATic
Enables assigning the IP address manually.
*RST:
AUTO
Example:
SYST:COMM:NETW:IPAD:MODE AUTO
The IP address is assigned automatically.
SYSTem:COMMunicate:NETWork:IPADdress:SUBNet:MASK
<netmask>
Effective only:
●
For the R&S
NRP LAN power sensors.
●
SYSTem:COMMunicate:NETWork:IPADdress:MODE
is set to
STATic
.
Sets the subnet mask.
Parameters:
<netmask>
Example:
SYST:COMM:NETW:IPAD:SUBN:MASK '255.255.255.0'
Sets
255.255.255.0
as subnet mask.
SYSTem:DFPRint<Channel>?
Reads the footprint file of the sensor.
Suffix:
<Channel>
.
1...4
Measurement channel if more than one channel is available.
Usage:
Query only