8.5
R&S ESU
Maintenance and Instrument Interfaces
Instrument Interfaces
Addressed Commands
The addressed commands are encoded 00 - 0F hex. They are only effective for
instruments addressed as listeners.
Instrument Messages
Instrument messages are transferred on the data lines of the GPIB if the "ATN"
control line is not active. ASCII code is used.
Structure and syntax of the instrument messages are described in chapter
. The commands are listed and explained in detail in chapter
“Remote Control – Description of Commands”
8.3.2
Printer Interface (LPT)
The instrument is equipped with a 25-pin LPT connector on the rear panel for con-
necting a printer. In
the pin assignment is described. The LPT interface is
compatible with the CENTRONICS printer interface.
Fig. 8.50 LPT connector pin assignment
Command
QuickBASIC command
Effect on the instrument
DCL (Device Clear)
IBCMD (controller%, CHR$(20))
Aborts the processing of the commands just received
and sets the command processing software to a
defined initial state. Does not change the instrument
settings.
IFC (Interface Clear)
IBSIC (controller%)
Resets the interfaces to the default setting.
LLO (Local Lockout)
IBCMD (controller%, CHR$(17))
The LOC/IEC ADDR key is disabled.
SPE (Serial Poll Enable)
IBCMD (controller%, CHR$(24))
Ready for serial poll.
SPD (Serial Poll Disable)
IBCMD (controller%, CHR$(25))
End of serial poll.
PPU (Parallel Poll Unconfigure)
IBCMD (controller%, CHR$(21))
End of the parallel-poll state.
Command
QuickBASIC command
Effect on the instrument
SDC (Selected Device Clear)
IBCLR (device%)
Aborts the processing of the commands just received and sets
the command processing software to a defined initial state. Does
not change the instrument setting.
GTL (Go to Local)
IBLOC (device%)
Transition to the "Local" state (manual operation).
PPC (Parallel Poll Configure)
IBPPC (device%, data%)
Configure instrument for parallel poll. Additionally, the
QuickBASIC command executes PPE/PPD.
1
14
13
25
D0
D1
D2
D3
D4
D5
D6
D7
ACK
BUSY
PE
SELECT
STROBE
AUTOFEED
ERROR
INIT
SELECT IN
GND
GND
GND
GND
GND
GND
GND
GND
Содержание 1129.7246.03
Страница 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Страница 25: ......
Страница 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Страница 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Страница 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Страница 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Страница 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Страница 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Страница 821: ...R S ESU Remote Control Programming Examples More Complex Programming Examples 7 32 Operating Manual 1302 6163 12 03 ...
Страница 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Страница 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Страница 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...