Operating Manual 1302.6163.12 - 03
6.87
R&S ESU
Remote Control – Description of Commands
CALCulate Subsystem
6.5.5
CALCulate:MATH Subsystem
The CALCulate:MATH subsystem allows to process data from the SENSe-subsystem in numeric expres-
sions.
The measurement windows are selected by CALCulate1 (screen A) and CALCulate2 (screen B).
CALCulate<1|2>:MATH[:EXPression][:DEFine]
(<expr>)
This command defines the mathematical expression for relating traces to trace1.
The
command switches the mathematical relation of traces on or off.
The measurement windows are selected via CALCulate1 (screen A) or 2 (screen B).
Parameter:
<expr>::= 'OP1 - OP2'
OP1 ::= TRACE1
OP2 ::= TRACE2 | TRACE3
Example:
"CALC1:MATH (TRACE1 - TRACE2)"
'Selects the subtraction of trace 1 from trace 2 in screen A.
"CALC2:MATH (TRACE1 - TRACE3)"
'Selects the subtraction of trace 1 from trace 3 in screen B.
Characteristics:
*RST value: -
SCPI: conform
Mode:
A-T
CALCulate<1|2>:MATH:POSition
-100PCT to 200PCT
This command defines the position of the result of the trace mathematics in the selected measurement
window. The indication is in % of the screen height, with 100% corresponding to the upper diagram
border.
Example:
"CALC:MATH:POS 50PCT"
'Sets the position in screen A to the horizontal diagram center.
Characteristics:
*RST value: 50 %
SCPI: device-specific
Mode:
A-T
CALCulate<1|2>:MATH:STATe
ON | OFF
This command switches the mathematical relation of traces on or off.
The measurement windows are selected via CALCulate1 (screen A) or 2 (screen B).
Example:
"CALC:MATH:STAT ON"
'Switches on the trace mathematics in screen A.
Characteristics:
*RST value: OFF
SCPI: conform
Mode:
A-T
Содержание 1129.7246.03
Страница 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Страница 25: ......
Страница 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Страница 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Страница 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Страница 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Страница 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Страница 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Страница 821: ...R S ESU Remote Control Programming Examples More Complex Programming Examples 7 32 Operating Manual 1302 6163 12 03 ...
Страница 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Страница 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...