800-621-8560

 

 

Unit Operation (cont.) 

 

To raise temperature in the refrigerated rail: 

A.  Push and hold the “set” button until 34 appears then release the “set” 

button. 34 is the current set point temperature. 

B.  Push and release the up arrow 2 times until 36 is displayed. Push and 

release  the  “set”  button  one  time.  The  new  set  point,  36,  will  flash  3 
times and then will be locked in. 

 

To lower temperature in the refrigerated rail: 

A.  Push  and  hold  the  “set”  button  until  34  appears  and  then  release  the 

“set” button. 34 is the current set point temperature. 

B.  Push and release the up arrow 2 times until 32 is displayed. Push and 

release  the  “set”  button  one  time.  The  new  set  point,  32,  will  flash  3 
times and then will be locked in. 

 
NOTE

:  

It is recommended to only make changes of 2 degree increments 

at a time. Allow for the unit to operate 24 hours between adjustments. If 
the 2 degree adjustment is not enough another adjustment can be made. 
The  maximum  highest  setting  is  38  degrees  and  the  minimum  lowest 
setting is 28 degrees. If the settings need to go above or below this point 
there  may  be  other  contributing  factors  as  to  the  cause  of  the 
temperature variances, please contact the factory at 1-800-621-8560. 

 

The base temperature can also be adjusted by the temperature control dial located 
on the front of the refrigeration coil inside the refrigerated base.  The thermometer 
for the base temperature is located in the mechanical housing (Figure 1, item b). 
 

To adjust temperature in the refrigerated base: 

A.  Locate  evaporator  coil  inside  cooler  between  the  mechanical  housing 

and the refrigerated base cabinet. 

B.  Thermostat is located at top front of evaporator coil. There are numbers 

to indicate settings. 

C.  Turn clockwise for colder setting (higher number). 
D.  Turn counterclockwise for warmer setting (lower number). 
 

NOTE: It is not recommended to turn the dial above 8 or below 1 on the 
temperature  control.  If  the  adjustments  still  do  not  result  in  proper 
temperature please contact the factory at 1-800-621-8560. 
 

Содержание PH120E2

Страница 1: ...bility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed damage Randell suggests that if you are suspicious of damage to make a notation on the delivery receipt It will be the responsibility of the consignee to file a claim with the carrier We recommend that you do so at once 525 South Coldwater Rd Weidman MI 48893 888...

Страница 2: ...st Congratulations on your recent purchase of Randell food service equipment and welcome to the growing family of satisfied Randell customers Our reputation for superior products is the result of consistent quality craftsmanship From the earliest stages of product design to successive steps in fabrication and assembly rigid standards of excellence are maintained by out staff of designers engineers...

Страница 3: ...erves the right to make changes in design and specifications without prior notice NOTICE Please read the entire manual carefully before installation If certain recommended procedures are not followed warranty claims will be denied MODEL NUMBER _________________________ SERIAL NUMBER _________________________ INSTALLATION DATE _____________________ The serial number is located on the interior rear ...

Страница 4: ...day window to allow for shipment installation and set up In the event equipment was shipped to a site other than the final installation site Randell will warranty for a period of three months following installation with proof of starting date up to a maximum of fifteen months from the date of purchase 2 Free ground freight of customer specified location for all in warranty parts within continental...

Страница 5: ... LABOR EXTENSION POLICY APPLIES Randell will provide reimbursement of labor invoiced to an ASA for any customer that has an optional labor extension of our standard warranty Contracted rates do apply Randell offers both 1 and 2 year extensions Labor extensions begin at the end of our standard warranty and extend out 9 months to 1 calendar year or 21 months to 2 calendar years from date of purchase...

Страница 6: ...fore fabrication of equipment In these special circumstances a revised quotation may be required to cover additional costs Failure to notify Randell before fabrication holds the dealer accountable for all additional charges CANCELLATIONS Orders canceled prior to production scheduling entered into engineering production and cancelled are subject to a cancellation charge contact factory for details ...

Страница 7: ...s and merchandise must be retained for inspection RETURNED GOODS Authorization for return must first be obtained from Randell before returning any merchandise Any returned goods shipment lacking the return authorization number will be refused all additional freight costs to be borne by the returning party Returned equipment must be shipped in original carton freight prepaid and received in good co...

Страница 8: ...imately 17 to height Model L D H Work Hgt Doors H P Voltage Amps Ref Qty NEMA Ship Wt PH120E2 120 40 57 35 4 24 115 60 1 16 R404A 40oz 5 20P 865 PH120E2 220 120 40 57 35 4 24 220 50 1 7 R404A 40oz Hardwire 865 PH120E2 1 120 40 57 35 4 24 115 60 1 16 R404A 40oz 5 20P 865 PH120E2 1 220 120 40 57 35 4 24 220 50 1 7 R404A 40oz Hardwire 865 ...

Страница 9: ...any stationary members 3 Unit must be properly leveled check all legs or casters to ensure they all are in contact with the floor while maintaining a level work surface Adjusting bullet feet heights or shimming casters may be necessary if the floor is not level NOTE Damage to equipment may result if not followed Randell is not responsible for damage to equipment if improperly installed 4 Plug in u...

Страница 10: ... located inside the mechanical housing NOTE It is important that a voltage reading be made at the compressor motor electrical connections while the unit is in operation to verify the correct voltage required by the compressor is being supplied Low or high voltage can detrimentally affect operation and thereby void its warranty NOTE it is important that your unit has its own dedicated line Condensi...

Страница 11: ...reduce the possibility of coil freeze up EVENING SHUT DOWN 1 Remove product from rail at the end of the day s preparation The product may be stored in the refrigerated base compartment or another cooler 2 Turn off rail with the switch located on the front mechanical panel of the unit 3 Rail cleaning may be performed at this time Randell has attempted to preset the cold controls to ensure that your...

Страница 12: ...another adjustment can be made The maximum highest setting is 38 degrees and the minimum lowest setting is 28 degrees If the settings need to go above or below this point there may be other contributing factors as to the cause of the temperature variances please contact the factory at 1 800 621 8560 The base temperature can also be adjusted by the temperature control dial located on the front of t...

Страница 13: ... coil in direction of fins normally vertically as to not damage or restrict air from passing through condenser 2 Clean fan blade on the condensing unit 3 Clean and disinfect drains with a solution of warm water and mild soap 4 Clean and disinfect drain lines and evaporator pan with a solution of warm water and mild soap Disconnect each end of the drain line and run the solution through it Do not a...

Страница 14: ...E ABRASIVE CLEANING SOLVENTS AND NEVER USE HYDROCHLORIC ACID MURIATIC ACID ON STAINLESS STEEL Proper maintenance of equipment is the ultimate necessity in preventing costly repairs By evaluating each unit on a regular schedule you can often catch and repair minor problems before they completely disable the unit and become burdensome on your entire operation For more information on preventive maint...

Страница 15: ...unifiedbrands net 15 Electrical Diagram ...

Страница 16: ...verload repeatedly tripping 4 Check outlet voltage Unit runs constantly 1 Condenser coil dirty 1 Clean coil 2 Condenser fan faulty 2 Service condenser motor Unit not cold enough 1 Temperature control set too high 1 Adjust control to lower setting 2 Temperature control faulty 2 Test control 3 Condenser coil dirty 3 Clean coil 4 Refrigerant leaking or contaminated 4 Call for service at 800 621 8560 ...

Страница 17: ...unifiedbrands net 17 Replacement Parts Pizza Hut Maketable PH120E2Prior to serial W27155 6 ...

Страница 18: ...18 18 18 18 800 621 8560 Replacement Parts Pizza Hut Maketable PH120E2Prior to serial W27155 6 ...

Страница 19: ...unifiedbrands net 19 Replacement Parts Pizza Hut Maketable PH120E2Prior to serial W27155 6 ...

Страница 20: ...20 20 20 20 800 621 8560 Replacement Parts Pizza Hut Maketable PH120E2 1 after serial W27155 6 Unit Exterior ...

Страница 21: ...unifiedbrands net 21 Replacement Parts Pizza Hut Maketable PH120E2 1 after serial W27155 6 Refrigerated Rail Top Section ...

Страница 22: ...22 22 22 22 800 621 8560 Replacement Parts Pizza Hut Maketable PH120E2 1 after serial W27155 6 Refrigerated Rail Condensing Unit ...

Страница 23: ...unifiedbrands net 23 Replacement Parts Pizza Hut Maketable PH120E2 1 after serial W27155 6 Coil Assembly ...

Страница 24: ...een 2 RP DSN002 19 Evaporator Fan Motor Rail EL MTR0101 20 Fan Mounting Box RP BRK0501 21 Left Duct Box PH120E2 only RP DCT0501 21A Center Duct Box PH120E2 only RP DCT0500 21B Right Duct Box PH120E2 only RP DCT0502 21C Duct Box interchangeable PH120E2 1 only RP DCT0801 22 Fan Register Front Right PH120E2 only RP REG0506 22B Fan Register Front Left PH120E2 only RP REG0507 22C Fan register One Piece...

Страница 25: ... for Rail RF CNT0101 46A Sensing Probes for Dixell Control RF CNT0505 47 Magnet Striker Plate HD STR9901 48 Rocker On Off Switch prior to Jan 2006 EL SWT140 48A Rocker On Off Switch after Jan 2006 EL SWT0502 49 Digital Thermometer for Base HD THR0006 50 Louver Door PH LVR120E2 50A Hinge assembly for louver door RP HNG9900 51 Magnetic Catch for Louver Door HD CTH9901 51A Striker Plate for Magnetic ...

Отзывы:

Похожие инструкции для PH120E2