background image

OPERATOR MANUAL

IMPORTANT INFORMATION, KEEP FOR OPERATOR

Information contained in this document is known to be current and accurate at the time of printing/creation.  Unified Brands recommends 

referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications. © 2018 Unified Brands. 

All Rights Reserved.  Unified Brands is a wholly-owned subsidiary of Dover Corporation.

2016 Gees Mill Road, Suite 200, Conyers, GA 30013

888-994-7636,  fax 888-864-7636

unifiedbrands.net

PART NUMBER PP MNL1803, REV. E (08/19)

This manual provides information for:

8000-290 & 9000W-290 SERIES 

PREP TABLES

THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.  READ, 
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS 
CONTAINED IN THIS MANUAL.

FOR YOUR SAFETY

 Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

WARNING

 

R290 flammable refrigerant in use. 

Improper installation, 

adjustment, alteration, service or maintenance can cause property 
damage, injury or death.  Read the installation, operating and maintenance 
instructions thoroughly before installing or servicing this equipment.

NOTIFY CARRIER OF DAMAGE AT ONCE

  It is the responsibility of the 

consignee to inspect the container upon receipt of same and to determine 
the possibility of any damage, including concealed damage. Unified 
Brands suggests that if you are suspicious of damage to make a notation 
on the delivery receipt. It will be the responsibility of the consignee to file 
a claim with the carrier. We recommend that you do so at once.

Manufacture Service/Questions 888-994-7636.

RETAIN THIS MANUAL FOR FUTURE REFERENCE

 

NOTICE: Due to a continuous program of product improvement, Unified Brands  
reserves the right to make changes in design and specifications without prior notice.
NOTICE: Please read the entire manual carefully before installation.  If certain 
recommended procedures are not followed, warranty claims will be denied.

MODEL NUMBER _________________________

SERIAL NUMBER _________________________

INSTALLATION DATE ______________________
The serial number is located behind the hinged vented 
door of the compressor machine compartment.  An 
example is shown here. 

EQUIPMENT DESCRIPTION

MODEL

PAN 

CAPACITY

1/3 SIZE

L

D

H

DOORS

STORAGE 

CU. FT.

HP

VOLT

AMPS

NEMA

SHIP 

WT.

WORK 

SURFACE

REAR OF UNIT 

(CLOSED COVER)

OVERALL 

(COVER OPEN)

8148N-290 

6

48”

33”

35”

44”

52.5”

(1)27”

9.0

1/3

115/60/1

6

5-15P

405

8260N-290 

8

60”

33”

35”

44”

52.5”

(2)24”

14.67

1/3

115/60/1

6

5-15P

459

8268N-290 

9

68”

33”

35”

44”

52.5”

(2)27”

17.76

1/3

115/60/1

6

5-15P

484

8383N-290 

11

83”

33”

35”

44”

52.5”

(2)24”,(1)21”

23.55

(2) 1/4

115/60/1

5.8

5-15P

585

8395N-290 

13

95”

33”

35”

44”

52.5”

(3)27”

28.18

(2) 1/4

115/60/1

5.8

5-15P

630

84111N-290 

15

111”

33”

35”

44”

52.5”

(3)24”,(1)21”

32.81

(2) 1/4

115/60/1

5.8

5-15P

675

MODEL

PAN 

CAPACITY

1/6 SIZE

L

D

H

DOORS

STORAGE 

CU. FT.

HP

VOLT

AMPS

NEMA

SHIP 

WT.

WORK SURFACE

(NO CUTTING BOARD)

REAR OF UNIT 

(NO COVER)

OVERALL 

8148W-290 

21

48”

33”

35”

46.5”

53.5”

(1)27”

9.0

1/3

115/60/1

6

5-15P

530

8268W-290 

30

68”

33”

35”

46.5”

53.5”

(2)27”

17.76

1/3

115/60/1

6

5-15P

595

8395W-290 

42

95”

33”

35”

46.5”

53.5”

(3)27”

28.18

(2) 1/4

115/60/1

5.8

5-15P

785

MODEL

PAN 

CAPACITY

1/6 SIZE

L

D

H

DOORS

STORAGE 

CU. FT.

HP 

(BASE & 

RAIL)

VOLT

AMPS

NEMA

SHIP WT.

9148W-290

18

48"

33"

46.5"

(1) 27"

5.5

 1/3

115/60/1

6

5-15P

405

9260W-290

24

60"

33"

46.5"

(2) 24"

9.8

 1/3

115/60/1

6

5-15P

465

9272W-290

30

72"

33"

46.5"

(2) 27"

11.2

 1/3

115/60/1

6

5-15P

510

Содержание 9000W-290 Series

Страница 1: ...estions 888 994 7636 RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Due to a continuous program of product improvement Unified Brands reserves the right to make changes in design and specifications wi...

Страница 2: ...necessary when ordering replacement parts or requesting warranty service 9 Allow your unit to operate for approximately 45 minutes before putting in food in the rail Allow 2 hours for base of the unit...

Страница 3: ...MAKE CHANGES OF 2 DEGREE INCREMENTS AT A TIME ALLOW FOR THE UNIT TO OPERATE 24 HOURS BETWEEN ADJUSTMENTS IF THE 2 DEGREE ADJUSTMENT IS NOT ENOUGH ANOTHER ADJUSTMENT CAN BE MADE IF THE SETTINGS NEED TO...

Страница 4: ...a monthly basis Condenser coils are a critical component in the life of the compressor and must remain clean to assure proper air flow and heat transfer Failure to maintain this heat transfer will af...

Страница 5: ...at the end of this manual When in doubt turn unit off and contact service at 888 994 7636 or tsrandell unifiedbrands net SYMPTOM POSSIBLE CAUSE PROCEDURE Unit does not run No power to unit Plug in uni...

Страница 6: ...ND REPAIR Leak check an R 290 system the same way you would an R 134a or R 404A system with the following exceptions 1 Do not use a Halid leak detector on a R290 system 2 Electronic leak detector must...

Страница 7: ...MED RAIL DBL COMP SYSM X X X X X 1 RP CNT1806 CONTOLLER PROGRAMMED BASE SGL COMPR SYSM X X X X X X X 1 RP CNT1807 CONTOLLER PROGRAMMED BASE DBL COMP SYSM X X X X 2 RF CNT1602 SENSOR COIL X X X X X X X...

Страница 8: ...UNIT X X X X X 5A RP SHD1806 SHROUD COND UNIT X 5B RP SHD1807 SHROUD COND UNIT X X X 5C RP SHD1808 SHROUD COND UNIT X 6 RP PNL1803 COVER ACCCESS SIDE CMPR L OR R X X X X 7 HD SHL180 SHELF 22 X 25 X X...

Страница 9: ...MAGNET X X X 4 HD BMP034 BUMPER RUBBER X X X 5 RP SHD1814 SHROUD COND UNIT X 5A RP SHD1815 SHROUD COND UNIT X 5B RP SHD1816 SHROUD COND UNIT X 6 HD SHL160 SHELF 19 X 25 X X 6A HD SHL180 SHELF 22 X 25...

Страница 10: ...REPLACEMENT PARTS 888 994 7636 8148N 290 8260N 290 8268N 290 8383N 290 8395N 290 84111N 290 8148W 290 8268W 290 8395W 290 ITEM SERVICE PART DESCRIPTION 1 RP FAN1801 FAN ASSIST ASSY X X X 2 RF FAN1401...

Страница 11: ...F FAN1401 CONDENSER FAN X X X X X X X X 5 RF FAN0703 FAN GUARD X X X X X X X X 6 RF FLT251 FILTER DRIER 1 4 DBL INLET X X X X X X X X 7 RP BRK1720 MOUNTING CLIP FILTER DRIER T07 1167 X X X X X X X X 8...

Страница 12: ...X X 2 RF CMP1604SC COMPRESSOR START COMPONENTS X X X X 3 RP CAP1802 CAP TUBE RAIL X X X X 4 RF FAN0601 CONDENSER FAN X X X X 5 HD GRD1610 FAN GUARD X X X X 6 RF FLT251 FILTER DRIER 1 4 DBL INLET X X...

Страница 13: ...X X X X X X 2 RP CAP1804 CAP TUBE BASE X X X X 2A RP CAP1803 CAP TUBE BASE X X X X X 3 RF FAN1401 FAN EVAPORATORS X X X X X X X X X 4 RP DRP107 EVAPORATOR DRAIN PAN X X X X X X X X X 5 RP PNL107 290 S...

Страница 14: ...RF COI107 EVAPORATOR COIL X X X 2 RP CAP1803 CAP TUBE BASE X X X 3 RF FAN1401 FAN EVAPORATORS X X X 4 RP DRP107 EVAPORATOR DRAIN PAN X X X 5 RP PNL107 290 SIDE COIL 8000N COMMON X X X 6 RP PNL108 290...

Страница 15: ...X X 2 IN GSK9902 GASKET 18 5 X 24 5 PUSH IN X X 2A IN GSK1025 GASKET 21 75 X 24 5 PUSH IN X X X 2B IN GSK1030 GASKET 24 5 X 24 5 PUSH IN X X X X X 3 HD HDL0103 DOOR HANDLE recessed X X X X X X X X X 4...

Страница 16: ...7 X X 2 IN GSK1025 GASKET 21 75 X 24 5 PUSH IN X 2A IN GSK1030 GASKET 24 5 X 24 5 PUSH IN X X 3 HD HDL0103 DOOR HANDLE recessed X X X 4 RP HNG9900 HINGE ASSY UNIVERSAL LEFT RIGHT X X X 4A RP HNG026 HI...

Страница 17: ...WER CARTRIDGE 24 X X X 2B RP MOD029A DRAWER CARTRIDGE 27 X X X X X 3 RF FRT9903 DRAWER FRONT 21 X X 3A RF FRT9904 DRAWER FRONT 24 X X X 3B RF FRT9905 DRAWER FRONT 27 X X X X X 4 RP FRM0301 DRAWER FRAM...

Страница 18: ...R HANDLE X X X 4 RP TRK05SM DRAWER TRACKS 1L 1R X X X 5 IN GSK1042 DRAWER GASKET 24 Top X 5A IN GSK1043 DRAWER GASKET 24 Bottom X 5B IN GSK1048 DRAWER GASKET 27 Top X X 5C IN GSK1047 DRAWER GASKET 27...

Страница 19: ...SCRIPTION 1 PB VLV1803 BALL VALVE 1 1 2 PVC FAMALE X X X X X X X X X X X X 2 PB TBG1801 TUBING 1 VINYL BLACK X X X X X X X X X X X X 3 HD CLM1801 CLAMP 1 OETIKER X X X X X X X X X X X X 4 HD CLP1801 C...

Страница 20: ...INSERT THREADED SOUTCHO X X X X X X 3 HD PIN001 PIN KEY PAN RAIL X X X X X X 4 RP DSN001 DRAIN SCREEN 2 X X X X X X 5 RP HNG006 HINGE PAN COVER SET OF 2 X X X X X X 6 HD PIN0101 PIN LOCATING 0 875 LEN...

Страница 21: ...HOD0310 HOOD COVER X 1G RP HOD1803 HOOD COVER X 1H HP HOD0609 HOOD COVER X 2 HD ROD100 HOOD COVER ROD W SINGLE BEND X X X X X 2A HD ROD200 HOOD COVER ROD W DOUBLE BEND X X 3 HD PIN107 PIN THREADED SO...

Страница 22: ...22 OM 8000 9000W SERIES PREP TABLES Wiring Diagram 8000 290 SINGLE COMPRESSOR...

Страница 23: ...23 OM 8000 9000W SERIES PREP TABLES Wiring Diagram 8000 290 DOUBLE COMPRESSOR...

Страница 24: ...24 OM 8000 9000W SERIES PREP TABLES Wiring Diagram 9000W 290...

Страница 25: ...25 OM 8000 9000W SERIES PREP TABLES Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...