18
refrigerator door
5.3
制冷温度
Inside temperature
Trk:开机温度 Trt:停机温度 Th:环境温度
实际开停机温度为屏显温度加下表中对应环温的偏移量。
Trk
:
Start-up temperature Trt: Shutdown temperature Th: Ambient temperature
The actual start-up and shutdown temperature is the screen temperature plus the corresponding offset of ambient
temperature in the table below.
环温
Cyclic temperature
各 室
Chambers
Th≤14℃ 14<Th≤21℃ 21<Th≤28℃ 28<Th≤35℃ Th>35℃
冷 藏 室 开
/ 停 偏 移
量 ( 设 定
2℃时)
Offset of the start-up
/shutdown
temperature
in refrigerating chamber
(when setting at 2 °C)
Trk
+1.5
+0.5
+0
+0.25
+1
Trt
+1.0
+0
-0.5
-0.5
+0.
冷 藏 室 开
/ 停 偏 移
量 ( 设 定
3-8℃时)
Offset of the start-up
/shutdown
temperature
in refrigerating chamber
(when setting at 3-8 °C)
Trk
+2
+1
+0
+0.5
+1
Trt
+1
+0
-1
-0.5
+0
冷冻室
开 / 停 偏
移量
Freezer
Offset of the start-up
/shutdown temperature
Tfk
-2.5
+0.5
+0
+0.5
-1
Tft
-9
-4.5
-3
-3.5
-3
5.4
除霜部件
Defrosting parts
除霜期
Defrosting period
初次除霜期
Initial defrosting period
正常除霜期
Normal defrosting period
通电 6 小时
6 hours
11~36
小时
11~36 hours
除霜传感器
Defrosting sensor
NTC
B3839
除霜温控器
Defrosting temperature controller
/
/
热熔丝
Thermal fuse
不可恢复
Can’t be restored
77
℃
冷冻室除霜加热器
Defrosting heater in freezing chamber
/
Defrosting heater
230V/250W
Содержание COMBI Series
Страница 6: ...6...
Страница 8: ...8...
Страница 9: ...9...
Страница 10: ...10 1 2 Safety instruction for refrigerant...
Страница 16: ...16 4 Terms 4 1 Definition of model None 4 2 Location of nameplate None...
Страница 19: ...19 5 5 Circuit diagram...
Страница 37: ...37 9 Function and operation 9 1 Operation panel SO BCD482WE ST_22031040001081 Inner display...
Страница 41: ...41 10 8 3 4 E4 1 CN1 2 10 8 3 4 E5 1 CN1 2 10 8 3 4 E6 1 CN8 2 3 4 E7 1 CN2 2 3 4 EH 1 CN2 2 3 4 EC EEPROM...
Страница 48: ...48 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic...
Страница 49: ...49 11 2 No working of compressor...
Страница 50: ...50 11 3 Inside frosting no defrosting 11 4 Inside frosting no defrosting Maintenance guidelines...
Страница 51: ...51 11 5 Light is not on...