Rear Panel Controls

MAINS SWITCH: Selects the country voltage. 

For 100-120VAC selections, change IEC fuse to T5A/250V fuse. 

For 220-240VAC selections, change IEC fuse to T2.5A/250V fuse. 

The H.T. Fuse remains unchanged. 

MAINS INPUT: AC wall power via included IEC cord to a grounded 

outlet

HT FUSE: Protection for AC power faults.

CH/BOOST: TRS switching jack for footswitch,. Tip to ground 

switching type. Tip=Channel and Ring=Boost select.

(2 button LED footswitch included)

LOOP: 1/4" tip to ground switching jack to bypass loop via 

external switching unit or footswitch (not included)

TEST POINT & BIAS: 

Using a Digital Multi Meter, set it to DC mV(olts) and insert the black probe 

into the COMMON meter jacks and the red probe into either TEST POINT 

meter jack. 

Set MASTER volume fully counter clockwise and take the amp off 

STANDBY, measure and set BIAS INSIDE 2 or BIAS OUTSIDE 2 located 

below the test points. Adjust the bias pots slowly.

Please note that the reading is the sum of 2 power tubes. Factory settings 

for 6L6 at either TEST POINT is 72mV, EL34 = 76mV, 6550/KT88 = 84mV.

T.5A FUSES: Fusing for the two inside pair and two outside pair of output 

tubes. In case of output tube failure, only the problem pair of tubes will 

drop out of circuit leaving you to finish your gig!