Unit Status Description
1. UNIT STATUS
a.
Enter
on the keypad gives the UNIT STATUS equipment selection.
2. UNIT STATUS equipment selection
a. Gives a choice of the system equipment.
i.
Next
or
Prev
buttons on the keypad to toggle the equipment selection.
b.
Enter
on the keypad at the the equipment selection screen gives access to individual units and their mode status,
available in the selected equipment family.
Note: A mode description screen shows for 5 seconds before continuing to the individual unit selection.
A= Availible
R= Run
F = Fault
Note: This screen is accessed from two directions.
1
. The normal direction outlined above.
2
. From the UNIT IN FAULT screen on the first level.
c. The numbers 1,2,3,4 … in top row shows the unit numbers
d. The letters A,R,F below each number gives the status of the equipment selection in the system, corresponding to the number above it.
Note: The OWL only shows the equipment configured in the system.
e.
Next
or
Prev
arrow keys on the keypad to toggle the equipment selection.
f.
Enter
on the keypad produces one of four different screens.
g.
Esc
on the keypad returns to the UNIT STATUS screen.
Select Enter
3. EQUIPMENT MODE STATUS
a.
Status - AVAIL
The equipment selected is not running but is available to run if needed.
b.
Status - RUNNING
The equipment selected is running.
c.
Status - FAULT
The equipment selected is not running and is in fault.
d.
Status - BYPASS
The equipment selected is running but manually put in bypass.
i.
This condition is reserved only for emergences. Running the pump during this condition will put the pump and warranty at risk.
Select the Prev Button
4. FAULT HISTORY
a.
Enter
on the keypad shows the unit selection history of faults starting with the most recent fault up to the last ten faults.
b.
Next
or
Prev
buttons on the keypad to toggle between the the range of faults.
c.
Esc
on the keypad gives the UNIT STATUS equipment selection screen.
Select the Prev Button
5. UNIT LIFETIME HOURS
a. Tells you how many hours the unit has run in its lifetime.
b.
Esc
on the keypad gives the UNIT STATUS equipment selection screen.
Select the Prev Button
6. UNIT HOURS UNTIL MAINTENANCE
a. Gives the number of run hours until maintenance is due on selected single units.
b.
Esc
on the keypad gives the UNIT STATUS equipment selection screen.
OPERATION AND MONITORING
Содержание OWL
Страница 1: ...OWL On Wall Logic User Guide and Installation...
Страница 9: ...Page 7 SOF_7 2 3 02 152 Effective date 30 May 08 OWL User Gude Notes...
Страница 18: ...SOF_7 2 3 02 152 Effective date 30 May 08 User Gude OWL Page 16 NOTES...
Страница 19: ...Page 17 SOF_7 2 3 02 152 Effective date 30 May 08 OWL User Gude NOTES...
Страница 26: ...SOF_7 2 3 02 152 Effective date 30 May 08 User Gude OWL Page 24 NOTES...