RAMVAC Bison Series Скачать руководство пользователя страница 18

Page 18

1061DOC  Rev C

Effective date: 6-Mar-14

User Guide 

RAMVAC Bison

®

 

RAMVAC

®

 Product Support Services

The DentalEZ Group and its employees are proud of the products we provide to the dental community. We stand behind these products with a 

warranty against defects in material and workmanship as provided below.

In the event that you experience difficulty with the application or operation of any of our products, please contact our customer service department 

at our expense at (866) DTE-INFO.

If we cannot resolve the issue by telephone, we will arrange for a representative to contact you or suggest that the product be returned to our fac

-

tory for inspection.

If product return or repair is required, we will provide you with a Return Authorization number and shipping instructions to return the product to 

the proper facility. If the product is under warranty we will ask you to provide proof of purchase such as a copy of your invoice. Please be sure to 

include the Return Authorization number on the package you are returning. Products returned without a return authorization number cannot 

be repaired.  

Freight costs for product returns are the responsibility of the customer. Products under warranty will be repaired or replaced, at our sole discretion, 

and returned at our expense. Products outside the warranty limits will be repaired and returned with costs invoiced to the customer. We are not 

responsible for shipping damages. We will, however, help you file a claim with the freight carrier. Written repair estimates are available. 

DentalEZ warrants all equipment and parts to be free of defects in material and workmanship, under normal usage, under the following terms:

 

RAMVAC Products: 

Warranty Period:

 RAMVAC

®

 Dental Vacuum System 

2 Years from date of installation*

 RAMVAC

®

 Vacuum Pumps only 

10 Years from date of installation*

 RAMVAC

®

 OWL

 

2 Years from date of installation*

 CustomAir

®

by RAMVAC®

 

6 Years / 4200 hours from date of installation*   

Please note the following additional terms of our warranty and return policy:

 

•  Warranties cover manufacturing defects only and do not cover defects resulting from abuse, improper handling, cleaning, care or

 

 

maintenance, normal wear and tear or non-observance of operating, maintenance or installation instructions.  Failure to use

 

 

authorized parts or an authorized repair facility voids this warranty.

 

•  Liability is limited to repair or replacement of the defective product at our sole discretion. All other liabilities, in particular

 

 

liability for damages, including, without limitation, consequential or incidental damages are excluded.

 

•  This warranty is in lieu of all other warranties, expressed or implied, including ANY IMPLIED warranties of merchantability or

 

 

fitness for a particular purpose. no employee, representative or dealer is authorized to change this warranty in any way or to

 

 

grant any other warranty.

WARRANTY REPAIRS:

Parts repaired or replaced on a product that is in warranty will be warranteed for the duration of that product’s original warranty.

NON-WARRANTY REPAIRS:

The warranty on parts either repaired or replaced on an out-of-warranty product will cover the repaired part only and will be for the timeframe of a 

new parts warranty period.

PRODUCT RETURN:

Opened products or product returns more than a year old cannot be returned for credit. There will be a 15% ($25.00 minimum) restocking charge 

on all items authorized for return.  

*When installed, operated and maintained in accordance with written instructions.

RAMVAC, Bulldog, Bison, FLOWCHECK, Ramclean and VACHECK are registered trademarks and InfiniTank, OWL and SlugBuster are trademark of RAMVAC Dental Products, Inc.

Содержание Bison Series

Страница 1: ...OPERATION Maintenance AND USER Manual Dental VACUUM System...

Страница 2: ...Cautions Thank you for selecting RAMVAC to serve your dental facility RAMVAC provides industry leading technology for convienient and efficient utility room equipment Invest a few minutes of your tim...

Страница 3: ...OXYGEN RICH ENVIRONMENT Large concentrations may cause a fire in the Vacuum Unit and may cause an exhaust hazard Never use your RAMVAC to scavenge flammable anesthetic gases Even small concentrations...

Страница 4: ...ital environment Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Mains power quality should be that of a typical commercial or hospital enviro...

Страница 5: ...cy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the ME EQUIPMENT o...

Страница 6: ...ntenance Schedule Page 10 Oil Fill Level Page 10 Cleaning the Vacuum System Page 11 Air Filters Page 11 Lubrication System Components Page 12 Oil Change Page 13 Check Oil Drip Rate Page 13 Check V Bel...

Страница 7: ...ed Electrical Ratings MODEL MOTOR THHN Wire Size1 PROTECTION2 3 Hp kW Phase Voltage4 Max Amps 50 ft 100 ft Breaker2 Fusetron3 Bison 3 5 7 60 Hz 3 0 2 2 1 230v 208 253 16 0 A 10 ga 10 ga 20 amp FRN 25...

Страница 8: ...Page 8 1061DOC Rev C Effective date 6 Mar 14 User Guide RAMVAC Bison MOTOR L1 MOTOR L2 LINE IN L1 LINE IN L2 GROUND Electrical Connection S2 Logic Board...

Страница 9: ...only Exhaust to Outside Weather Cap required S2 Electrols Mounted on Bison Power Power to Motor Gases Continue to Pump Facility Vacuum Piping Remote Control Signal Liquids and Solids Drain when Vacuu...

Страница 10: ...Buttons STARTS UNIT STOPS UNIT FROM RUNNING TOGGLES SCREENS IN DISPLAY RESETS ALARMS AND MAINTENANCE TIMER S2 Shutdown Faults for Bison Fault System Status Corrective Action Maintenance Due System ru...

Страница 11: ...personnel to repair parts Maintenance Overview To read correctly get eye level with sight glass while unit is sitting level and check that oil level is even with the head of the red arrow Add or drai...

Страница 12: ...lids separator routinely and clean when dirty Cleaning Unit 1 Always disconnect the power from the equipment prior to cleaning 2 Some parts on the vacuum get hot during operation Provide the unit ampl...

Страница 13: ...brication System supplies oil drop by drop through Drippers to the pump Used oil is discharged back into the Oil Reservoir as a mist separated from the exhaust filtered and recirculated Change oil eve...

Страница 14: ...il change and every time the 1000 hour Filter Maintenance displays Drip rate should be 1 to 3 drops per minute at each Dripper when the Bison vacuum unit is thoroughly warmed up the vacuum setting is...

Страница 15: ...l Terminals Toggle Switch or other non illuminated switch option Air Switch Air Light Common F 24 VDC G 24 VDC H DC Common Illuminated Remote Switch Note Maximum wire length for low voltage 18 gauge w...

Страница 16: ...Void the Warranty 4 Clear the Moisture Allow the Separating Tank to drain Lift off the Vacuum Controller remove Main Air Filter Clean out any remaining moisture Remove Moisture Sensor by twisting and...

Страница 17: ...ature High Vacuum Pressure Improper Oil Lower ambient temperature Lower vacuum pressure Change to recommended oil Oil Comes Out Exhaust Incorrect Exhaust Installation Oil Reservoir Overfull Bypassed M...

Страница 18: ...MVAC Dental Vacuum System 2 Years from date of installation RAMVAC Vacuum Pumps only 10 Years from date of installation RAMVAC OWL 2 Years from date of installation CustomAir by RAMVAC 6 Years 4200 ho...

Страница 19: ...Page 19 1061DOC Rev C Effective date 6 Mar 14 RAMVAC Bison User Guide...

Страница 20: ...A Brand of the The Integrated Supplier PHONE 866 DTE INFO www dentalez com 212 North Main Street 800 5 RAMVAC Spearfish SD 57783 FAX 605 642 3776 www ramvac com 1061DOC Rev C Effective date 6 Mar 14 2...