33
• Sleep
1
Sleep mode can only be set in Cool, Heat, and Dehumidify ('Dry') mode.
2
When the system runs in Sleep mode, it will stop after 8 hours operation, canceling the Sleep setting. If the
system has a programmed Timer-OFF setting when Sleep mode runs, one of two things will occur:
· If Timer-OFF is set to less than 8 hours away when Sleep mode is engaged, the system will run in Sleep
mode only until the TIMER-OFF shutdown triggers.
· If Timer-OFF is set to more than 8 hours away when Sleep mode is engaged, the system will run in Sleep
mode until it ends, turning off the system and canceling the Timer-OFF setting trigger.
3
When the Sleep mode is selected with Cooling mode, if the room temperature not less than 26ºC, the
setting temperature will not be adjusted, otherwise, the setting temperature will be raised by 1ºC per hour, but
the max setting temperature raise is 1ºC.
4
When the Sleep mode is select with Heat mode, the setting temperature will be decreased by 1ºC per hour
during the successive 3 hour, but the max setting temperature decrease is 3ºC.
5
When the appliance operate with Sleep mode, the indoor fan run in the LOW setting, and the air flow
direction same as the last setting and the temperature and air flow direction can be adjusted by user. The
Running indicator will be flashed 10 times per 1 Hz frequency, then all the indicators turn OFF except the Sleep
light after 5 min elapse. Those indicators will be recovery when the temperature or Time setting is adjusted,
after the setting, the indicators will be lit in 10 sec, then turn OFF.
• Automatic run (SMART) mode
When the appliance operates in Smart Mode, the air flow direction can be adjusted.
1
H/C appliance
a.
When the temperature setting is 26ºC, the unit will run in Cool mode if the room temperature exceeds 26ºC.
b.
When the room temperature exceeds 23ºC, but is below 26ºC, it will run in Dry mode.
(It will switch to Automatic setting after 3 min LOW air volume running.)
c.
When the room temperature exceeds 21ºC, but is below 23ºC, it will run in Fan only mode, with the air volume
set to LOW and fan speed can be adjusted.
d.
When room temperature is not more than 21ºC, it will run in Heat mode, and the temperature is set to 22ºC.
2
Cool only appliance
a.
When the room temperature exceeds 26ºC, it will be ran in Cool mode, and the temperature is set to 26ºC.
b.
When the room temperature exceeds 23ºC, but not more than 26ºC, it will be operated in the Dry mode.
c.
When the room temperature is not more than 23ºC, it will be operated in the Fan only, the air volume
set to LOW and the fan speed can be adjusted
After the appliance start the smart operation, the setting temperature can be adjusted 2ºC or 7ºC (based on the remote
mode; min accuracy is 1ºC) up and down base on the automatic temperature setting, also the presetting temperature of
PCB circuit.
In case of the specific operation selected, it could be re-select the other modes after the compressor ceased for 5
min or the setting temperature changed.
Содержание Celiera AS-09TR3SVDDH
Страница 1: ...2018 Revision...
Страница 19: ...19 3 Product Pictures and Dimensions 3 1 1 Product Pictures Indoor Units Unit View DF Panel VQ Panel...
Страница 26: ...26 1854605 1854698...
Страница 27: ...27 4 2 3 Outdoor Diagrams 1854707...
Страница 43: ...43 6 2 2 Indoor DC Fan Motor Outdoor DC Fan Motor 6 2 3 Outdoor DC Fan Motor...