background image

20

www.ramsetinc.com

RAMSET

R

AM 3

00 U

L

BILL OF MATERIAL FOR:  RAM 300 UL

45

50-173

Lexan Glass Cover

1

46

50-174

Polyethylene Cover

1

47

50-175

10" Cast Iron Pulley

1

48

50-202

4L V Belt # 350

1

49

50-215

Rocker Switch

1

50

50-263

1/4" x 5" Key Way

1

51

50-265

3/16" x 3/4" Key Way

2

52

50-275

1 1/2" UHMW Spacer

1

53

50-277

Foot Release Guide Bracket

1

54

50-278

Foot Pedal Release

1

55

50-279

Under Foot Release Bracket

1

56

50-282

Arbor Release

1

57

50-283

4 Pin Disc Release

1

58

50-295

#8 Self-Tap Sheet Metal Screw

2

59

50-299

Radio Receiver Terminal

1

60

50-304

120/240 Intelligate Transformer

1

61

50-321

1/2" Hex Head Lock Nut

5

62

50-335

Spring 1/4" x 2" for Pedal Release

1

63

50-336

2" UHMW Ring

1

64

50-337

1/2" x 1 1/2" Hex Head Bolt

1

65

50-339

1" x 2" Plastic Cap

2

66

50-510

Outlet Switch Cover

1

67

50-511

120 VAC Double Outlet

1

68

50-519

3/8" x 1 1/2" Carriage Bolt

8

69

50-529

#6 x 2" Machine Screw

2

70

50-537

1/4" Hex Head Lock Nut

3

71

50-538

5/16" Fender Washer

3

72

50-539

5/16" Socket Head Screw

1

73

50-540

5/16" Hex Head Lock Nut

2

74

50-545

1/4" x 1/2" Phillips Machine Screw

1

75

50-546

Gate Bracket

1

76

50-777

Intelligate Control Board

1

ITEM

PART #

PART DESCRIPTION

RAM 300 UL

Ramset_Man300.qxd  4/18/05  1:07 PM  Page 22

Содержание RAM 300 UL

Страница 1: ...FOR CLASS I II III IV VEHICULAR GATE OPERATORS Ramset_Man300 qxd 4 18 05 1 06 PM Page 1 ...

Страница 2: ...www ramsetinc com Ramset_Man300 qxd 4 18 05 1 06 PM Page 2 ...

Страница 3: ...IONS WARNING To reduce the risk of injury or death 1 READ AND FOLLOW ALL INSTRUCTIONS 2 Never let children operate or play with gate controls Keep the remote control away from children 3 Always keep people and objects away from the gate NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE 4 Test the Vehicular Gate Operator monthly The gate MUST reverse on contact with a rigid object or stop when an obj...

Страница 4: ... OR LOOP DETECTOR CHECK THE E R D SENSITIVITY MAKE SURE THAT ALL AREAS AROUND THE GATE ARE SAFE AND SECURE SUCH AS THE FRONT REAR AND TRAVEL AREA COMMUNICATE WITH THE END USER INSTRUCT THE END USER ON HOW TO SAFELY OPERATE ALL FUNCTIONS OF THE OPERATOR INSTRUCT THE END USER ON HOW TO SAFELY USE THE EMERGENCY RELEASE CLEARLY LABEL AND IDENTIFY THE CIRCUIT BREAKER FOR THE OPERATOR SHOW THE END USER ...

Страница 5: ...security feature to prevent unauthorized use f All warning signs and placards must be installed where visible in the area of the gate g For Vehicular Gate Operators utilizing a non contact sensor in accordance with 30A 1 1 Type B1 non contact sensor photo electric sensor or the equivalent 1 See instructions on the placement of non contact sensors for each type of application 2 Care shall be exerci...

Страница 6: ...dustrial limited access vehicular gate operator class III A vehicular gate operator or system intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public Restricted access vehicular gate operator class IV A vehicular gate operator or system intended for use in a guarded industrial location or building s...

Страница 7: ...www ramsetinc com 5 RAMSET WARNING Do not exceed the specifications RAM 300 UL RAM 300 UL Ramset_Man300 qxd 4 18 05 1 06 PM Page 7 ...

Страница 8: ...justed depending on local soil conditions 1 Construct form for mounting pad according to dimensions shown in Figure 1 and 2 2 Locate mounting pad according to dimensions given in illustration 3 Level top edge of form 4 Set reinforcing bars and wire mesh 5 Allow pad to cure for 48 hours and remove forms 6 Note conduits 6 above concrete pad Figure 2 Figure 1 Ramset_Man300 qxd 4 18 05 1 06 PM Page 8 ...

Страница 9: ... wires direct to outlet HOOKUP ELECTRICAL POWER Figure 4 Gate travel is adjusted by loosening the limit Cams and positioning them until proper gate travel has been achieved GATE TRAVEL ADJUSTMENT Clutch tension bolts need to be tightened to a minimum of 40 lbs above weight of gate in order to avoid slipping Outlet Leads CAUTION Ramset_Man300 qxd 4 18 05 1 06 PM Page 9 ...

Страница 10: ...w ramsetinc com RAMSET RAM 300 UL SPACE REQUIRED FOR A STANDARD GATE IN THE OPEN POSITION Figure 7 STANDARD INSTALLATION FOR GATES FROM 14 TO 18 IN LENGTH Figure 6 Ramset_Man300 qxd 4 18 05 1 06 PM Page 10 ...

Страница 11: ...IN LENGTH 9 www ramsetinc com RAMSET RAM 300 UL MINIMUM SPACE REQUIRED FOR COMPACT INSTALLATION Figure 8 Figure 9 20 in minimum space required between open gate and wall for this compact installation Ramset_Man300 qxd 4 18 05 1 06 PM Page 11 ...

Страница 12: ... on the ground floor prevents gate from closing when vehicle is in loop area Exit Loops on the ground floor opens gate when vehicle crosses loop area Photoelectric Safety Sensor Photo Eye prevents the gate from closing when any object interrupts the beam Ramset Gate Operators should not be installed without non contact sensing devices such as Loop Detectors photo electric sensors or the equivalent...

Страница 13: ...ontrol Board Three pushbuttons are located under the dip switches for operation of the gate see Figure 11 The opening stop and closing buttons can be utilized to set limit switches and verify proper system operation when installing or servicing an operator PUSHBUTTON CONTROLS MASTER SLAVE INSTALLATION L E D s light up when Opening Closing or Stopped Figure 12 Figure 11 Set Dip Switch C8 Slave Mode...

Страница 14: ...y maintains a closed contact Dip Switch B 3 CONSTANT WARN Constant warning when gate is in motion Sw Function OFF No effect ON Triggers the prewarn relay to maintain a closed contact while gate is in motion Dip Switch B 6 Not in use at this time Leave in the Off position Dip Switch B 7 Not in use at this time Leave in the Off position Dip Switch B 8 3 4 HP E R D Sw Function OFF Low E R D for 3 4 h...

Страница 15: ...on OFF Master mode single gate operation All peripheral devices are to be connected to the master operator ON Slave mode used to synchronize operation between two gates Commands are received from the master through a 3 wire shielded cable not provided with unit Dip Switch C 7 LEFT RIGHT Sw Function OFF Left hand installations All operators come factory set for left hand operation ON Right hand ins...

Страница 16: ...nc com RAMSET RAM 300 UL TERMINAL STRIP CONNECTION Figure 14 PHOTO EYE can be used as a Reverse Loop or as a Backplane protection Look for the appropriate hookup on the Board Ramset_Man300 qxd 4 18 05 1 07 PM Page 16 ...

Страница 17: ...tor is cleared Once the detector is cleared the operator will resume normal operation If triggered twice before reaching a limit switch the alarm will sound for 6 minutes and the control board will not accept any commands After the 6 minutes the 24 VDC is removed from the alarm connection and the board resets to normal operation Terminal 9 and 10 LIMIT 1 LIMIT 2 Direction depends on Dip Switch C 7...

Страница 18: ...rd is powered by a separate mounted 24 VAC transformer This allows no neces sary board modifications between 110 VAC and 220 VAC single phase applications Some of the functions of the Control Board are 0 60 seconds automatic close timer self adjusting E R D with low and high setting constant warning pre warning secure close one pass open close delay left right hand operation plug in loop detectors...

Страница 19: ... open and close are normally open connections and the stop is a nor mally closed connection remove jumper wire when connecting 3 button station Common and stop are also used with a photo eye used to protect the back plane of the operators JP9 Input Power 1 2 24 VAC power Connection from external transformer to power Control Board JP4 JP5 JP8 Reverse Exit Phantom Sensor Used with the Ramset ILD 24 ...

Страница 20: ... 51 51 11 10 1 37 18 18 15 74 75 64 19 40 41 42 20 21 21 44 72 45 76 47 48 49 66 67 50 31 3 25 30 23 63 35 35 22 4 8 8 18 17 16 17 17 18 68 68 69 29 33 70 55 73 71 54 62 23 58 53 56 59 70 71 60 57 9 61 61 61 65 52 34 Figure 16 PARTS DIAGRAM 39 46 38 RAM 300 UL Ramset_Man300 qxd 4 18 05 1 07 PM Page 20 ...

Страница 21: ...01 3 8 Lock Washer 8 21 50 103 3 8 18 Hex Head Lock Nut 12 22 50 104 5 16 Hex Head Nut 4 23 50 105 6 Hex Head Nut 4 24 50 107 6 x 3 8 Machine Screw 6 25 50 110 1 2 14 x 2 1 2 Hex Head Bolt 3 26 50 111 1 2 14 x 3 1 2 Hex Head Bolt 1 27 50 112 1 2 Flat Washer 4 28 50 114 1 4 20 Socket Head Screw 2 29 50 115 Polyethylene Cup Cover 1 30 50 117 1 x 2 x 34 Rectangular Metal Tube 1 31 50 118 1 x 2 x 46 R...

Страница 22: ...2 59 50 299 Radio Receiver Terminal 1 60 50 304 120 240 Intelligate Transformer 1 61 50 321 1 2 Hex Head Lock Nut 5 62 50 335 Spring 1 4 x 2 for Pedal Release 1 63 50 336 2 UHMW Ring 1 64 50 337 1 2 x 1 1 2 Hex Head Bolt 1 65 50 339 1 x 2 Plastic Cap 2 66 50 510 Outlet Switch Cover 1 67 50 511 120 VAC Double Outlet 1 68 50 519 3 8 x 1 1 2 Carriage Bolt 8 69 50 529 6 x 2 Machine Screw 2 70 50 537 1...

Страница 23: ...al blocked 2 Area not suitable for type of Receiver SOLUTION 1 Reset circuit bleaker 2 Replace 1 2 amp fuse 3 Return Control Board for repair 1 A for 1 2 hp motors turn dip switch A 4 On B for 3 4 hp motors turn dip switch B 8 On 1 Disconnect all accessories including plug ins using the Exit input If problem persist contact Ramset 1 Disconnect all accessories including plug ins using the Rev Loop ...

Страница 24: ...ns should use a separate entrance 3 Always keep people children and objects away from the gate while the gate is in operation No one should cross the area of a moving gate 4 All opening devices such as a keypad cardreader should not be installed close to the gate where the gate could possibly cause injury 5 Use warning signs attached on both sides of the gate WARNING Ramset_Man300 qxd 4 18 05 1 07...

Страница 25: ...n No one should cross the area of a moving gate Use the emergency release only when the gate is not moving Make sure when using the foot release or hand crank the circuit breaker for the operator is turned off Have the technician give you a demonstration of how to use the emergency release Keep gates properly maintained Have a qualified gate technician service the gate operator and gate hardware e...

Страница 26: ...BACK UP SYSTEM Heavy Duty Industrial Will open gate and maintain open until power is reestablished RAMSET RPI This power supply will open and close gates on power outages UPHILL HINGES UPHILL ARMS To be used under uneven conditions Ramset_Man300 qxd 4 18 05 1 07 PM Page 26 ...

Страница 27: ...www ramsetinc com Ramset_Man300 qxd 4 18 05 1 07 PM Page 27 ...

Страница 28: ...Ramset_Man300 qxd 4 18 05 1 07 PM Page 28 ...

Отзывы: