RAMSET RAM 30 30 Скачать руководство пользователя страница 6

4

RAM 30-30

RAMSET

www.ramsetinc.com

vehicular horizontal slide-gate operator (or system) 

- A vehicular gate operator (or system) that 

controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or 

exit to a drive, parking lot, or the like.

vehicular swing-gate operator (or system)

 - A vehicular gate operator (or system) that  controls a 

gate which swings in an arc in a horizontal plane that is intended for use for vehicular entrance or exit 

to a drive, parking lot or the like.

Residential vehicular gate operator-Class I 

- A vehicular gate operator (or system) intended for 

use at a home of one-to four single family dwellings, or a garage or parking area associated there  

with.

Commercial/general access vehicular gate operator-Class II 

- A vehicular gate operator (or sys-

tem) intended for use in a commercial location or building such as a multi-family housing unit (five or 

more single family units), hotels, garages, retail stores, or other buildings serving the general public.

Industrial/limited access vehicular gate operator-Class III

 - A vehicular gate operator (or system) 

   intend ed for use in an industrial location or building such as a factory or loading dock area or other 

locations not intended to service the general public.

Restricted access vehicular gate operator-Class Iv 

- A vehicular gate operator (or system) in-

tended for use in a guarded industrial location or building such as an airport security area or other re-

stricted access locations not servicing the general public, in which unauthorized access is prevented 

via supervision by security personnel.

A 3 wire, 120 VAC electrical circuit with a 15 amps independent circuit breaker for single operator 

and a 20 amps for Master/Slave. Low voltage control wires must be run in a separate conduit to the 

operator.

NOTE: 

 

Always consult and follow all local building and electrical codes prior to installation.

CLASSES OF vEhICULAR GATE OPERATORS

RECOMMENDED ELECTRICAL CONNECTION

RECOMMENDED WIRE GAUGE

AMPERES

INPUT POWER

MOTOR hP

RUN

START

120V Single Phase

3/4

8.0

8.7

220V Single Phase

1

4.7

5.0

MAXIMUM CONDUIT DISTANCE IN FEET

USING COPPER WIRE BY WIRE SIZE

14ga.

12ga.

10ga.

8ga.

Up to 50’

50-150’

150-250’

450’

Up to 100’

50-350’

350-650’

800’

Содержание RAM 30 30

Страница 1: ...RAMSET www ramsetinc com...

Страница 2: ...RAMSET www ramsetinc com...

Страница 3: ...ience or appropriate training with gate operators WARNING WARNING To reduce the risk of injury or death 1 READ AND FOLLOW ALL INSTRUCTIONS 2 Never let children operate or play with gate controls Keep...

Страница 4: ...vice such as a photo eye or loop detector Check the e r d Sensitivity for proper adjustments Make sure that all areas around the gate are safe and secure such as the front rear and travel area Communi...

Страница 5: ...r or easily accessible controls shall have a security feature to prevent unauthorized use g The stop and or reset button must be located in the line of sight of the gate Activation of the reset contro...

Страница 6: ...l limited access vehicular gate operator Class III A vehicular gate operator or system intend ed for use in an industrial location or building such as a factory or loading dock area or other locations...

Страница 7: ...ght 20 3000 lbs gate traveling speed Approx 90 opening in 16 sec motor 3 4 Hp 1 Hp duty cycle Continuous operating temperature 10 F to 160 F power failure release Knob Release or Battery Back Up overa...

Страница 8: ...ars and wire mesh 5 Allow pad to cure for 48 hours and remove forms 6 Note conduits 6 above concrete pad Installation specifications GROUND LEVEL ELECTRICAL CONDUIT FOR MASTER SLAVE DEDICATED CONDUIT...

Страница 9: ...ates from 8 to 16 in Length hookup electrical power GATE TRAVEL ADJUSTMENT Figure 4 WARNING Do not exceed the specifications The warranty on your unit will be void if the installation exceeds the reco...

Страница 10: ...nside Property Outside Property 4 ft Length is the minimum space required between the open gate to the wall for this standard installation Steel Square Tubing 4x4 Supplied Bracket Gate Rotation Center...

Страница 11: ...hotoelectric Safety Sensor Photo Eye prevents the gate from closing when any object interrupts the beam Figure 10 Ramset Gate Operators should always be installed with non contact sensing devices such...

Страница 12: ...to open Stop Pressing this button will cause the gate to stop moving Closing Pressing this button will cause the gate to close Reset E R D Board Push all three pushbuttons for approximately 5 seconds...

Страница 13: ...vity ON ON Least Sensitive Dip Switch B 2 PRE WARN Used with JP2 Relay Connections pins 7 8 Triggers a relay for an alarm or light not included for 3 sec onds before the gate will move in any directio...

Страница 14: ...Normal Operation ON When power is lost then regained control board checks status of the gate If open and safety de vices are cleared gate will close automatically Dip Switch C 7 LEFT RIGHT Sw Function...

Страница 15: ...RAM 30 30 13 RAMSET www ramsetinc com SAFETY For RAM 30 30 For RAM 30 30 3 4 Hp Figure 14 Terminal strip Connection...

Страница 16: ...cleared Once the detector is cleared the operator will resume normal operation If triggered twice before reaching a limit switch the alarm will sound for 6 minutes and the control board will not accep...

Страница 17: ...y left right hand operation plug in loop detectors and RS485 three wire master slave connection Figure 15 plug in Power Transformer 40VA Dipswitches Automatic Timer Prewarn Constant Warning Secure Clo...

Страница 18: ...e wire Shielded cable is needed to run from the A B Common JP7 of the master P C B to the A B Common JP7 of the slave P C B JP10 Loop Inputs 1 2 Reverse 3 4 Exit 5 6 Phantom Use with ILD 24s Loop wire...

Страница 19: ...RAM 30 30 17 RAMSET www ramsetinc com Figure 16 Parts Diagram 10 28 15 42 45 46 16 43 2 5 6 17 8 38 35 37 32 39 27 19 1 26 7 4 21 20 31 22 18 23 14 24 41 25 9 3 13 32 34 33 36 34 39 40 13 12 29 11 44...

Страница 20: ...etal 1 1 19 800 60 00 Transformer 120 240V to 18VAC 40VA UL 1 1 20 800 60 11 Switch Power 220 VAC 1 21 800 60 15 Outlet Switch Combo 1 22 800 62 00 Control Board Intelligate 1 1 23 800 64 00 Edge Conn...

Страница 21: ...art PART DESCRIPTION 3 4 HP 1 HP 41 800 75 00 ARM ASSEMBLY 1 1 42 800 28 00 Arm Metal Tubing 1 x 2 x 32 1 1 43 800 28 01 Arm Metal Tubing 1 x 2 x 42 1 1 44 800 54 10 Bracket Channel 1 3 4 x 10 1 1 45...

Страница 22: ...3 Always keep people children and objects away from the gate while the gate is in operation No one should cross the area of a moving gate 4 No opening devices such as a keypad cardreader etc should b...

Страница 23: ...hildren and objects away from the gate while the gate is in operation No one should cross the area of a moving gate Use the emergency release only when the gate is not moving power is turned off to th...

Страница 24: ...ll the way 1 Motor direction wrong 1 Signal blocked 2 Area not suitable for type of Receiver SOLUTION 1 Reset circuit breaker 2 Replace 1 2 amp fuse 3 Return Control Board for repair 1 A for 1 2 hp mo...

Страница 25: ...gate s closed Goose Necks Square 16 ga Available in 48 pad mount or 66 in ground Used for mounting keypads phone entry systems card readers etc ILD 24S Loop Detector Plug in loop detector with sensiti...

Страница 26: ...9116 De Garmo Ave Sun Valley CA 91352 Tel 818 504 2533 Fax 818 504 1141 www ramsetinc com...

Отзывы: