Battery packs do require routine maintenance and care to maximize their useful life and 

maintain warranty coverage. Read and follow the guidelines in this manual to safely use 

your lithium-ion battery packs and achieve battery life span.

Lithium-Ion Battery Maintenance Guidelines

According to leading cell manufacturers (LG, Samsung, Panasonic), the estimated life of a 

lithium-ion battery is 500 charge cycles. When stating approximate useful life of a battery 

in units of “charge cycles,” cell manufacturers define this as the point where the battery 

capacity (Ah) is reduced to 80% of original. This means battery is not “dead” after 500 

charge cycles, but runtime is significantly reduced, and replacement should be considered.

Partial discharge of lithium-ion batteries is fine. There is no “memory effect” and the battery 

does not need periodic full discharge cycles to prolong life.

Overview

Storage

When storing, remove battery packs from fan and store in a dry and cool location. Avoid 

extreme temperatures.

• Recommended Storage Temperature: 5

o

C to 20

o

C (41

o

F to 68

o

F)

• Maximum relative humidity during storage: 90% RH

NOTE: all batteries self-discharge during storage. Higher temperature (>20

o

C or 68

o

F) reduce 

the battery storage life.

Lithium-ion batteries should be stored in a charged state, ideally around 30% state of 

charge (SoC). See “Storage/Transport Mode” section of this manual for easy discharging 

steps to follow before storing battery packs.

Long-term (>6 months) storage of battery packs is not recommended. When a battery pack 

has been unused for 6 months, check the charge status and either charge or dispose of the 

battery as appropriate.

Recommendations 

• Battery packs will last significantly longer when run in pairs (two battery packs per fan) 

as there is 50% less discharge current per pack.

• As with any equipment, batteries will wear out faster with heavy use. Depth of 

Discharge (DoD) determines the cycle count of the battery. The smaller the discharge 

(low DoD), the less stress is enacted on the chemistry of the battery and the longer the 

battery will ultimately last. Ideally, operators should avoid full discharges and charge 

the battery after every use.

Maintenance and Disposal

• DO NOT disassemble the ventilator for maintenance reasons.  

• Do not loosen screws on control box without contacting Euramco customer service. 

They are torqued to a setting to achieve water tightness. 

• Completely unravel power cord and place unit on a flat, stable surface. Clean ventilator 

periodically to remove accumulated dust or particles from ventilator guards, impeller 

blade and heat sink in rear of controller (ribbed). Use only biodegradable detergents. If 

power washing, avoid controller housing especially gaskets and control panel.

• Contact factory for replacement parts and installation instructions. To order spare 

parts call Euramco Group 

+1.619.670.9590 or [email protected]  

• Always dispose of your battery pack according to federal, state and local regulations.

  

• Even discharged batteries contain some energy. Before disposing of, use electrical tape 

to cover the terminals to prevent the battery pack from short circuit. 

• Properly dispose of battery packs when necessary. Contact your local hazardous 

materials e-waste collection department for details or proper disposal of rechargeable 

batteries.

Содержание EL5500

Страница 1: ...San Diego Luxembourg Dubai Ningbo Singapore FlowPath Control GEN II Owner s Manual ALL PURPOSE BATTERY VENTILATOR ...

Страница 2: ...Interface 6 Adjusting Angle 7 Operational Modes 8 AC Operation 8 DC Operation 8 Connection of Battery Pack 8 9 Battery Operation Procedures 10 Run Time 11 Charging Procedure 12 Battery Status Indicator Lights 13 Battery Pack Protection 13 Storage Transport Modes 14 How to Activate Storage Transport Mode 14 AC Power Cord 15 Operating Limitations 15 Lithium Ion Battery Maintenance Guidelines 16 Over...

Страница 3: ... top of controller controls all functions Specifications LB9106 Hot Surface Do Not Touch Heat Sink or Lights Warning Labels Safety Precautions Electrical shock hazard Do not open enclosures DO NOT START with signs of visible damage Blower is not intended for operation in explosive atmospheres Wear ear protection when close by Keep body parts and loose objects away from intake of fan Do not move wh...

Страница 4: ...g STORAGE MODE Storage Transport Mode L R BAT FAULT PUSH FOR WAKE STOP PUSH FOR MAX AC PWR DC PWR FAULT NO PWR STORAGE MODE MAX IntellisenseTM E3 LIGHTS SPEED 1 2 3 4 5 6 AC PWR DC PWR MAX FAULT NO PWR STORAGE MODE AC PWR DC PWR MAX FAULT NO PWR STORAGE MODE AC PWR DC PWR MAX FAULT NO PWR STORAGE MODE AC PWR DC PWR MAX FAULT NO PWR STORAGE MODE AC PWR DC PWR MAX FAULT NO PWR STORAGE MODE AC PWR DC...

Страница 5: ...the warranty 1 Connect the fan to an AC power source 2 Status LED Light will automatically turn green displaying the status Ventilator is connected on AC Power Supply 3 Start the ventilator by using the Speed Control knob to the desired speed Note You can keep the batteries on their location without charging the battery Battery Indicator Lights will turn off because there is no battery charging wh...

Страница 6: ... the status The unit will return to sleep mode if not used within 10 minutes The ventilator starts at the lower speed 0 Speed will vary by 11 levels from 11 highest to 0 off Turn clockwise to increase speed At level 11 the highest if keep turning the control knob clockwise the speed will not change it will stay at highest speed all the time To slow down turn counterclockwise If you want to increas...

Страница 7: ...to cool down in between charging and discharging L R BAT FAULT PUSH FOR WAKE STOP PUSH FOR MAX AC PWR DC PWR FAULT NO PWR STORAGE MODE MAX IntellisenseTM E3 LIGHTS SPEED Make sure the battery pack is connected correctly to the ventilator as described above in Connection of Battery Pack The next step is to leave the ventilator off During charging the battery indicator lights will flash The battery ...

Страница 8: ...Storage Transport Mode can be engaged with either one 1 or two 2 battery packs installed on the fan How to activate Storage Transport Mode AC Power Cord CORD STORAGE This battery fan was designed to replace corded AC fans optimizing cordless operations The AC power cord is designed to be removable for the convenience of those users who choose to operate cordless The AC power connector is a Push Pu...

Страница 9: ...used for 6 months check the charge status and either charge or dispose of the battery as appropriate Recommendations Battery packs will last significantly longer when run in pairs two battery packs per fan as there is 50 less discharge current per pack As with any equipment batteries will wear out faster with heavy use Depth of Discharge DoD determines the cycle count of the battery The smaller th...

Страница 10: ...ress protection Quickly inspect for obvious damage after every use If damage is noted contact Authorized Service Center for inspection testing and maintenance Damage to gasket may compromise water ingress protection increasing risk of pack failure Do not store in same compartment with combustible or highly flammable material as gasoline and diesel oil Liquid damage is not covered under warranty Ac...

Страница 11: ...kg ft m tilt cfm m hr EX50Li 18 46 0 8 22x21x12 56x53x30 EL5500 EL5500 230 45 20 2798 14 4 3 13 9 635 16 370 AC EX50Li 18 46 0 8 22x21x12 56x53x30 EL5500 EL5500 230 45 20 3045 14 4 3 9 10 120 17 194 DC Euramco Group 2746 Via Orange Way Spring Valley CA 91978 USA Ph 1 619 670 9590 www Euramco com Page 1 of 1 DECLARATION OF CONFORMITY BATTERY POWERED FANS Year of Manufacture 2020 Manufacturer Euramc...

Страница 12: ...loded View EX50Li Gen II 24 15 16 16 15 26 22 21 14 37 TOWARD TILT PLATE CONCAVE SIDE 22 6 4 2 33 28 29 35 36 32 F 3 17 19 5 57 10X 51 5X 58 30 8X 40 23 5X 12 50 31 8 OF EL6015 63 62 3 OF EL6015 See parts index pg 24 ...

Страница 13: ... 250 NYLON WASHER 062 37 FF99432 6 x 1 2 P TRUSS SMS PLTD STL 51 FZ9500461 PT POWER CORD QUICK DISCONNCT Type E F Schuko 57 EL CUS 4762 PIPE PLUG 3 8 NPT MACHINED 58 FH93816 MACH MOTOR CONTROLLER ASSY G2 62 EMC E55010G2 Telescoping Handle Wheel Kit EX50Li Factory Install 63 EL6015 Plug Types The EX50Li is suitable for worldwide applications Both a voltage frequency converter is not needed The unit...

Страница 14: ...ter 5326 Contern Luxembourg Phone 352 621377200 Fax 352 26008056 theteam euramcosafety com MIDDLE EAST UAE Jebel Ali FTZ Dubai Phone 1 619 670 9590 x114 Fax 1 619 670 7345 theteam euramcosafety com CHINA A11 No 1 Jinxi Road Qingshuipu Zhenhai Zhejiang Ningbo China 315221 Phone 86 574 87979390 Fax 86 574 87979391 saleschina euramcosafety com MADE IN THE USA Use with all US Firefighting literature ...

Отзывы: