Connection to city gas supply line
The gas inlet pipe connector thread size is 0.5 inches. (1/2 inches). Please seal all joints with thread
sealing tape to prevent leakage.
Gas Leakage Warning
Once the cooktop installed, make sure all the connections are properly sealed, use soapy water to test
leakage, & never use fire. Your licensed technician should have gas leakage test equipment / gauge to
perform this inspection.
Electrical Connection
This unit requires 110V AC power source for electric ignition. The power cord must be positioned so
that it does not reach a temperature in excess of 50℃ than room temperature at any point.
Before actual connection make sure that:
The fuse and electrical system can withstand the load required by the hob;
The electrical supply system is equipped with a ground wiring.
The plug or switch are easily accessible.