DSP Specifications

Output Power Configuration

AS 2K3

AS 1K5

(Selectable by channel)

CH-A

CH-B

CH-A

CH-B

8 ohm

1500W

400W

400W

400W

4 ohm

1500W

750W

750W

750W

2  ohm

750W

750W

750W

750W

Bridge 8 ohm

1500W

Bridge 4 ohm

-

1500W

Total Harmonic Distortion  

<0.05%

<0.05%

Efficiency

>90%

>90%

Damping Factor 

(20-500Hz @8Ω)

>400

>400

Voltage Gain

32dB

32dB

Operational Mains voltage

85-265V AC/50-60Hz

85-265V AC/50-60Hz

Consum. @4Ω, 1/8 r.p., 230V AC

1.7 A

1.2 A

Power Factor

>0.95

>0.95

Efficiency

>90%

>90%

Dimensions

External Plate WxH

130x443 mm

130x443 mm

Internal  Enclosure WxHxD

100x423x55 mm

100x423x55 mm

Occupied Volume (optional case)

2 l

2 l

Weight

1.5 kg

1.5 kg

Connections:

XLR Input, XLR Link, powerCON True1 in-out, USB, 2x RJ45, barrier strip (in optional case)

Protections:

Turn-on transients, Over-heating, DC, RF, Short-circuit, mismatched loads, ICL™, PMS™

Overall:

• High performance 96kHz 120dB 32 bits AD/DA converters
• 64 bit double-precision 96kHz DSP process
• 0.6ms minimum process latency time
• Up to 3000 taps custom FIR process
• Up to 562ms total audio delay 

Input Section:

• Gain, Mute and Phase inversion
• Input Delay: 0 to 140 meters (406ms)
• Input EQ: 31 GEQ + 8 PEQ (Parametric, Shelving, LP, HP, BP,

SB, AP)

Output Section:

• Crossover Filters: FIR and IIR (up to 48dB/oct, Butterworth /

Linkwitz-Riley / Bessel)

• Output Delay: 0 to 18 meters (52ms) per channel
• Output IIR EQ: 12 filters per channel (Parametric, Shelving,

LP, HP, BP, SB, AP)

• Output FIR EQ: 20 filters per channel (Parametric, Shelving,

LP, HP, BP, SB, AP), or Custom up to 3000 taps

• RMS, Peak, and Thermal limiter per channel

Amplifier Specifications

Control & Monitor:

• Standby mode for remote turn-on
• Real time impedance monitor
• Stby., Signal, Lim, Clip, Temp and Prot monitor
• Input, Output, Temperature and Current meters

Communications:

• Two ports Ethernet switch for daisy chain

connection

• USB 2.0, Type B connector

Overall:

• 20 Manufacturer preset memories library
• 5 User preset memories library
• 4 Quick Preset selection
• Manufacturer/Installer/User passwords
• Independent selectable output power per

channel (Z dependant)

• User control groups for virtual Equalization,

Gain and Delay

• Zone management for library, stand-by and

alerts information

• Smaart

®

analysis software integration

RAM_OCS Control

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

The exclamation point inside
an equilateral triangle indica-
tes the existence of internal
components whose substitu-
tion may affect safety.

The lightning and
arrowhead symbol
warns about the
presence of uninsulated
dangerous voltage.

To avoid fire or electrocution risk do not expose
the unit to rain or moisture. To avoid electric
shock, do not open the unit. No user serviciable
parts inside. In the case of disfunction, have the
unit checked by qualified agents. Class I device.